The Foxboro P0916FK, also cataloged as the P0916FK Cable Assembly, operates as a dedicated hardware component for field signal conditioning and pressure transmitter interconnectivity within Foxboro I/A Series platforms. Configured for signal transmission in process instrumentation loops, it handles 4-20 mA HART loop protocol outputs across pressure spans from 0-100 psi up to 0-10,000 psi. The physical execution relies on 316L stainless steel wetted parts and a 1/2" NPT conduit connection to interface pressure sensors with system controllers.

Hardware Specifications

Parameter Specification
Model P0916FK
Brand Foxboro
Origin USA
Operating Temp -40 to +85 deg C
Power Consumption Loop-powered via 4-20 mA circuit
Output Signal 4-20 mA, HART protocol
Pressure Range 0-100 psi to 0-10,000 psi
Measurement Accuracy +-0.1% of full scale
Electrical Connection 1/2" NPT conduit

DCS Process Control and 4-20 mA HART Loop Protocol

The Foxboro P0916FK incorporates high-integrity wiring for continuous analog signal transmission and digital bi-directional telemetry via the 4-20 mA HART loop protocol. Built to interface with Foxboro DCS platforms, the assembly maintains +-0.1% full-scale measurement accuracy while preserving channel-to-channel isolation across remote terminal blocks. The 316L stainless steel structural interface and isolated conduit routing suppress ground loops and electromagnetic interference, allowing diagnostic data and pressure variables to pass to system I/O modules without signal attenuation across the operating temperature spectrum of -40 to +85 deg C.

Frequently Asked Questions

Q: What conduit size is required for securing the electrical connection on the P0916FK?

A: The electrical interface utilizes a standard 1/2" NPT conduit connection for direct entry into explosion-proof or industrial junction boxes.

Q: How is remote configuration executed through the P0916FK hardware interface?

A: Diagnostic queries and calibration parameters are transmitted over the 4-20 mA loop conductors using standard HART handheld communicators or DCS asset management software.

Field Installation Guidelines

  1. Inspect the 316L stainless steel threads and NPT connection point for debris before installation into the process tap or conduit housing.
  2. Engage the 1/2" NPT conduit thread manually, completing a minimum of 5 full turns engagement to achieve proper mechanical seal and ingress protection.
  3. Route the 4-20 mA signal wires through dedicated grounded metal conduits, keeping them separate from high-voltage AC power lines.
  4. Terminate the overall cable shield at a single ground reference point inside the DCS cabinet to mitigate ground loop noise.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more