Foxboro P0916MZ I/A Series Interface CableFoxboro P0916MZ I/A Series Interface CableFoxboro P0916MZ I/A Series Interface Cable
Foxboro P0916MZ I/A Series Interface Cable
Foxboro P0916MZ I/A Series Interface Cable
Foxboro P0916MZ I/A Series Interface Cable

Foxboro P0916MZ I/A Series Interface Cable


Only 10 left - Selling fast

PRODUCT SKU : P0916MZ

PRODUCT TYPE : Interface Cables

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Foxboro P0916MZ, also cataloged as the P0916MZ Interface Cable, operates as a dedicated hardware component for 2 Mbps high-speed data transmission between local modules and P0940XA or P0940XB bus couplers within I/A Series platforms.

Hardware Specifications

Parameter Specification
Model P0916MZ
Brand Foxboro
Origin USA
Weight 0.12 kg (0.26 lbs)
Dimensions Length 1.0 m
Transmission Rate 2 Mbps Serial Bus
Compatible Hardware P0940XA / P0940XB Bus Couplers
Operating Temp -20 to +70 deg C
Power Consumption Passive (0 W)

Channel-to-Channel Isolation & Signal Integrity

The Foxboro P0916MZ interface cable provides high-frequency noise immunity for 2 Mbps deterministic fieldbus communication streams. Designed with optimized characteristic impedance and full-coverage shield construction, the assembly mitigates high-frequency signal attenuation and suppresses cross-talk between high-speed serial pairs. It maintains physical channel-to-channel isolation and signal ground reference integrity between connected I/A Series modules and P0940XA or P0940XB coupling units.

Frequently Asked Questions

Q: Can the Foxboro P0916MZ cable be disconnected or connected while the baseplate network is live?

A: Yes, the cable carries low-voltage passive bus signals, enabling hot-plug capability at the connector level without causing backplane power disruption.

Q: Is 2 Mbps the maximum rated data transfer speed for the P0916MZ cable assembly?

A: Yes, the internal wire pair twisting and impedance matching are specified for deterministic 2 Mbps serial fieldbus throughput to P0940XA/B modules.

Field Installation Guidelines

  1. Inspect cable pin connectors for physical alignment and clean contact pins before joining with module headers.
  2. Maintain a minimum bend radius of 75 mm throughout the cable routing to avoid conductor strain and differential impedance shifts.
  3. Route the 1.0 m cable through dedicated low-voltage wire ducts, maintaining a minimum 300 mm clearance from high-voltage AC lines.
  4. Fully seat connector housings into the P0940XA or P0940XB receptacles, tightening retention screws hand-tight.
  5. Ensure shield drain connections link directly to cabinet ground terminals following single-point grounding rules.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more