ATD5A-00 S1 Yokogawa 32-Point KS Cable Interface AdapterATD5A-00 S1 Yokogawa 32-Point KS Cable Interface AdapterATD5A-00 S1 Yokogawa 32-Point KS Cable Interface Adapter
ATD5A-00 S1 Yokogawa 32-Point KS Cable Interface Adapter
ATD5A-00 S1 Yokogawa 32-Point KS Cable Interface Adapter
ATD5A-00 S1 Yokogawa 32-Point KS Cable Interface Adapter

ATD5A-00 S1 Yokogawa 32-Point KS Cable Interface Adapter


Only 10 left - Selling fast

PRODUCT SKU : ATD5A-00 S1

PRODUCT TYPE : Cable Interface Adapters

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Yokogawa ATD5A-00 S1, also cataloged as the ATD5A-00 32-Point KS Cable Interface Adapter, operates as a dedicated hardware component for 32-point digital signal routing and wiring harness interfacing within CENTUM VP DCS platforms.

Hardware Specifications

Parameter Specification
Model ATD5A-00 S1
Brand Yokogawa
Origin Japan
Point Capacity 32 Channels / Points
Connection Interface KS Cable Interface
Weight 0.30 kg
Dimensions 10.2 cm x 3.8 cm x 10.2 cm
Operating Temp -20 to 70 deg C
Power Consumption Passive Interface Assembly (Host Rack Powered)

Yokogawa Channel-to-Channel Isolation & DCS Signal Routing

Yokogawa digital cabling adapters route high-density field I/O signals directly into backplane bus nodes while maintaining signal path integrity. Channel-to-channel isolation architecture prevents noise coupling and ground potential differences across parallel wiring paths. The 32-point terminal interface operates seamlessly alongside 4-20 mA HART loop protocol pairs and digital I/O lines, ensuring channel isolation and preventing signal attenuation or latency degradation during continuous real-time scanning cycles.

Frequently Asked Questions

Q: Does the ATD5A-00 S1 adapter require an external power supply for passive signal routing?

A: No, the adapter functions as a passive physical routing and interface unit for 32-point KS multi-core cables, deriving low-level bias and signal power directly from the connected DCS I/O module backplane.

Q: How is ground isolation maintained across the 32 signal points on the adapter?

A: Galvanic and channel-to-channel isolation limits are maintained by internal trace separation on the internal substrate, preventing loop currents from circulating between adjacent field channels.

Field Installation Guidelines

Mount the interface unit securely to the designated DIN-rail or cabinet subpanel assembly. Ensure that multi-core KS cables are fully seated and locked with their retaining screws to prevent pin disconnection under vibration. Maintain single-point shield grounding at the enclosure earth busbar, and route signal cables away from high-voltage AC lines in accordance with field installation standards.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more