Skip to content

What are you looking for?


You may also like

PanelView 600 Standard Operator Terminal | Allen-Bradley 2711-T6C20L1PanelView 600 Standard Operator Terminal | Allen-Bradley 2711-T6C20L1PanelView 600 Standard Operator Terminal | Allen-Bradley 2711-T6C20L1
PanelView 600 Standard Operator Terminal | Allen-Bradley 2711-T6C20L1
PanelView 600 Standard Operator Terminal | Allen-Bradley 2711-T6C20L1
PanelView 600 Standard Operator Terminal | Allen-Bradley 2711-T6C20L1

PanelView 600 Standard Operator Terminal | Allen-Bradley 2711-T6C20L1


Only 10 left - Selling fast

PRODUCT SKU : 2711-T6C20L1

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 2711-T6C20L1 belongs to the PanelView 600 series of standard operator terminals. Designed for industrial environments, it provides a compact, reliable interface with touch input and Ethernet connectivity.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line PanelView 600

  • Product Family PanelView Standard Terminals

  • Part Number 2711-T6C20L1

  • UPC 611320575309

  • Weight 2.00 lbs (0.91 kg)

  • Display Type Active Matrix TFT with Cold Cathode Fluorescent (CCF) backlight

  • Backlight Field replaceable, rated 50,000 hours half-life at 25 °C (77 °F)

  • Display Size 5 inches

  • Display Area 115 x 87 mm (4.54 x 3.43 in.)

  • Resolution 320 x 240 pixels

  • Display Color Color

  • Input Type Touchscreen

  • Touchscreen Capacity 128 cells (16 columns x 8 rows)

  • Touch Cell Size 20 x 30 pixels

  • Application Memory 190 KB runtime, 240 KB nonvolatile (objects, text, bitmaps)

  • Communication Ports Ethernet, RS-232 (printer)

  • Communication Protocols EtherNet/IP and RS-232 printer interface

  • Input Voltage Range 18–32 V DC (24 V DC nominal)

  • Input Power 18–32 V DC supply

  • Heat Dissipation 24 W max (1.0 A at 24 V DC)

  • Operating Temperature 0–55 °C (32–131 °F)

  • Communication Cable Ethernet cable

  • Series A through L

  • Lifecycle Status Discontinued/Obsolete

Application Scenarios

  • Compact operator interface for small to mid-sized machines

  • Process visualization in manufacturing environments

  • Touch-based control for legacy automation systems

FAQ

  • Q: What is the display resolution?  A: 320 x 240 pixels.

  • Q: Can the backlight be replaced?  A: Yes, it is field replaceable with a rated half-life of 50,000 hours.

  • Q: What communication options are available?  A: Ethernet and RS-232 printer ports.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more