Overview

The Allen-Bradley 1747-DCM is a high-performance Direct Communication Module designed for SLC 500 controllers. It enables robust Remote I/O (RIO) communication with reliable speed and signal integrity, supporting standard and non-extended node operation modes.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Series / Product Line: SLC 500

  • Model / Part Number: 1747-DCM

  • Module Type: Direct Communication Module (DCM)

  • Weight: 1.00 lb (0.45 kg)

  • Operating Temperature: 0°C to 60°C (32°F to 140°F)

  • Supported Protocol: Remote I/O (RIO)

  • Transmission Rates: 57.6K baud up to 10,000 ft; 115.2K baud up to 5,000 ft

  • Communication Cable: Belden 9463 or equivalent

  • Terminating Resistor: 82 Ω or 150 Ω

  • Compatible Controllers: SLC 500 Fixed and Modular style

  • Operation Modes: Standard and Non-Extended Node

  • LED Indicators: FAULT, COMM

  • Backplane Current: 360 mA @ 5VDC

  • Communication Port: Universal Remote I/O Adapter

  • Connector Type: 6-Pin Phoenix Connector

Key Features

  • Enables direct communication between SLC 500 controllers and remote I/O networks

  • Supports long cable runs up to 10,000 ft with adjustable baud rates

  • LED status indicators for fault and communication monitoring

  • Compatible with standard SLC 500 fixed and modular controllers

  • Compact form factor suitable for chassis-based installation

Application Scenarios

The 1747-DCM is ideal for:

  • Remote I/O communication in distributed control systems

  • Applications requiring reliable high-speed data transmission over long cable runs

  • Integration with both modular and fixed SLC 500 controllers

Similar Model Comparison

  • 1747-DCM – Standard Direct Communication Module for SLC 500

  • 1747-DCMA – Advanced DCM with extended node support

  • 1747-DCM/B – Optional variants with enhanced baud rate and signal diagnostics

FAQs

Q: Which cable types are recommended for this module?
A: Belden 9463 or any equivalent shielded twisted-pair cable.

Q: Can it operate on extended node SLC 500 systems?
A: Supports standard and non-extended node modes; extended nodes require advanced variants.

Q: What indicators are available for module status?
A: FAULT and COMM LEDs provide immediate operational feedback.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more