PRODUCT SKU : 1746-NIO4I

PRODUCT TYPE : Analog Input/Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1746-NIO4I is a precision analog input/output module designed for SLC 500 control systems. It combines two high-resolution analog inputs and two analog outputs in a single module, providing accurate signal processing for industrial automation applications. The module is engineered for fast update rates, reliable backplane performance, and robust isolation for safe operation.

Technical Specifications

Module Details

  • Model: 1746-NIO4I

  • Manufacturer: Allen-Bradley

  • Product Type: Combination Analog Input/Output Module

  • I/O Configuration: 2 analog inputs / 2 analog outputs

Input & Output Ranges

  • Input Ranges: ±20 mA, ±10 V DC

  • Output Range: ±10 V DC - 1 LSB

  • Resolution: 16 bits (input), 14 bits (output)

  • Update Time: 512 µs per channel

  • Bandwidth: 10 Hz

  • Step Response: 60 ms input, 2.5 ms output

Electrical & Backplane

  • Backplane Current (5 V): 55 mA

  • Backplane Current (24 V): 145 mA

  • Tested Isolation Voltage: 500 V

Physical & Environmental

  • Weight: 1.00 lb (0.45 kg)

  • Mounting: Standard SLC 500 chassis slot

Applications

The 1746-NIO4I is ideal for systems requiring precise analog monitoring and control, including process control loops, sensor signal processing, and actuator control in manufacturing automation. Its combination I/O configuration allows flexible integration in compact system designs.

FAQ

Q: How many analog channels does the module provide?
A: 2 analog inputs and 2 analog outputs.

Q: What is the input signal range?
A: ±20 mA and ±10 V DC.

Q: How fast is the module update time?
A: 512 microseconds per channel.

Q: Is the module isolated for safety?
A: Yes, it has tested isolation voltage of 500 V.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more