Skip to content

What are you looking for?


You may also like

Allen-Bradley FLEX 1794-IE12 12-Channel Analog Input ModuleAllen-Bradley FLEX 1794-IE12 12-Channel Analog Input ModuleAllen-Bradley FLEX 1794-IE12 12-Channel Analog Input Module
Allen-Bradley FLEX 1794-IE12 12-Channel Analog Input Module
Allen-Bradley FLEX 1794-IE12 12-Channel Analog Input Module
Allen-Bradley FLEX 1794-IE12 12-Channel Analog Input Module

Allen-Bradley FLEX 1794-IE12 12-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1794-IE12

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1794-IE12 is a 12-point analog input module from the FLEX I/O series designed for scalable distributed control applications. It provides high-resolution signal acquisition for both voltage and current inputs, offering accuracy and reliability for analog process measurements in industrial automation environments.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: FLEX I/O

  • Model / Part Number: 1794-IE12

  • Product Type: Analog Input Module

  • Number of Inputs: 12 single-ended, non-isolated channels

  • Resolution:

    • Voltage: 320 µV per count

    • Current: 0.641 µA per count

  • Conversion Method: Successive approximation

  • Input Current Range: 4–20 mA

  • Calibration: Factory-calibrated (no user adjustment required)

  • Status Indicators: One dual-color (green/red) LED for power and module status

  • Isolation: Non-isolated single-ended channels

  • Dimensions (L x W x H): 5.33 cm × 9.4 cm × 9.4 cm

  • Shipping Weight: 2 kg

Key Features

  • 12-channel analog input for scalable FLEX I/O applications

  • Supports both current and voltage signal processing

  • Successive approximation ensures fast and accurate conversions

  • Factory-calibrated for plug-and-play reliability

  • Compact and modular design simplifies installation and system expansion

Application Scenarios

  • Process control and monitoring in manufacturing plants

  • Integration with PLC systems for analog signal acquisition

  • Measurement of temperature, pressure, and flow in distributed I/O systems

  • Ideal for applications requiring high-density analog input capability

FAQs

Q: How many channels does the 1794-IE12 support?
A: It offers 12 single-ended, non-isolated analog input channels.

Q: What signal ranges does it accept?
A: The module accepts both voltage and current signals, including standard 4–20 mA current inputs.

Q: Is calibration required?
A: No user calibration is necessary; the unit is factory-calibrated for long-term accuracy.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more