Skip to content

What are you looking for?


You may also like

Allen-Bradley 440N-Z21SS2HN Guardmaster SensaGuard Non-Contact Safety Interlock SwitchAllen-Bradley 440N-Z21SS2HN Guardmaster SensaGuard Non-Contact Safety Interlock SwitchAllen-Bradley 440N-Z21SS2HN Guardmaster SensaGuard Non-Contact Safety Interlock Switch
Allen-Bradley 440N-Z21SS2HN Guardmaster SensaGuard Non-Contact Safety Interlock Switch
Allen-Bradley 440N-Z21SS2HN Guardmaster SensaGuard Non-Contact Safety Interlock Switch
Allen-Bradley 440N-Z21SS2HN Guardmaster SensaGuard Non-Contact Safety Interlock Switch

Allen-Bradley 440N-Z21SS2HN Guardmaster SensaGuard Non-Contact Safety Interlock Switch


Only 10 left - Selling fast

PRODUCT SKU : 440N-Z21SS2HN

PRODUCT TYPE : Safety Switche

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 440N-Z21SS2HN functions as a high-integrity safety solution within the SensaGuard non-contact interlock family. This switch utilizes advanced Radio Frequency Identification (RFID) technology to monitor the position of machine guards without physical contact. We supply this unit as 100% Brand New original factory stock, ensuring your safety circuits achieve Category 4/PLe ratings (ISO 13849-1) for high-risk industrial applications.

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Line Guardmaster SensaGuard
Actuator Type Rectangular Plastic Actuator
Sensing Distance 18 mm (0.71 in.)
Code Type Standard Code
Connection Type 6-inch Pigtail with 8-Pin Micro (M12) Connector
Input Voltage 24V DC (+10% / -15%)
Current Consumption 50 mA
Diagnostic Indicators Integrated LED for Door Status and Faults
Safety Rating PLe, SIL 3, Cat 4
Weight 0.35 lbs (0.16 kg)

Engineering Advantages

  • RFID Coded Security: The 440N-Z21SS2HN employs RFID technology to provide high resistance to tampering. Unlike traditional magnetic switches, this "Standard Code" unit prevents unauthorized bypass using simple magnets, ensuring operators cannot easily circumvent the safety system.

  • Superior Misalignment Tolerance: The 18mm sensing distance accommodates significant door sag or guard misalignment. This hardware feature eliminates nuisance trips in heavy-duty environments where vibration or mechanical wear causes minor shifts in guard positioning over time.

  • Simplified Series Wiring: Integrated OSSD (Output Signal Switching Device) outputs allow for the series connection of multiple SensaGuard switches while maintaining the highest safety rating. This architecture reduces the required I/O on your safety controller and simplifies cable management across large machine cells.

  • Visual Diagnostic Feedback: A multi-color LED provides immediate status updates directly on the switch body. Technicians identify "Guard Closed," "Guard Open," or "Internal Fault" states at a glance, drastically reducing troubleshooting time during commissioning or downtime events.

  • Washdown Ready Construction: The rectangular plastic housing resists common industrial chemicals and high-pressure washdown procedures. Its non-contact nature removes mechanical wear points, making it ideal for food processing, pharmaceutical, and packaging lines where hygiene and uptime are paramount.

FAQs

  • What is the difference between "Standard" and "Unique" coding?

    The 440N-Z21SS2HN uses Standard Coding, meaning any SensaGuard actuator of the same type will trigger the switch. For applications requiring a one-to-one match between a specific sensor and its actuator to prevent all forms of bypass, you should select the "Unique Coded" version.

  • Can I mount this switch directly onto metal surfaces?

    Yes, but metallic environments can slightly reduce the effective sensing distance. We recommend maintaining a small non-metallic buffer or testing the 18mm range during installation to ensure consistent switching performance.

  • Is the 6-inch pigtail replaceable?

    No, the pigtail is permanently molded into the switch body to maintain its IP environmental rating. However, the standard 8-pin Micro (M12) connector allows you to use standard extension cables for long-distance runs to the control cabinet.

  • How do I confirm this unit is brand new?

    We guarantee every 440N-Z21SS2HN arrives in its Original Allen-Bradley Factory Packaging with intact serial numbers. As a 100% Brand New item, the housing will show zero mounting marks, and the RFID pairing has never been initiated in a field environment.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more