Skip to content

What are you looking for?


You may also like

Allen-Bradley 2711PC-T10C4D1 | PanelView Plus 1000 Compact Operator TerminalAllen-Bradley 2711PC-T10C4D1 | PanelView Plus 1000 Compact Operator TerminalAllen-Bradley 2711PC-T10C4D1 | PanelView Plus 1000 Compact Operator Terminal
Allen-Bradley 2711PC-T10C4D1 | PanelView Plus 1000 Compact Operator Terminal
Allen-Bradley 2711PC-T10C4D1 | PanelView Plus 1000 Compact Operator Terminal
Allen-Bradley 2711PC-T10C4D1 | PanelView Plus 1000 Compact Operator Terminal

Allen-Bradley 2711PC-T10C4D1 | PanelView Plus 1000 Compact Operator Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711PC-T10C4D1

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 2711PC-T10C4D1 PanelView Plus 1000 Compact Operator Terminal is a rugged HMI solution designed for industrial environments. Featuring a 10.4-inch color TFT display with resistive touchscreen input, it provides reliable operator interface functionality for monitoring and control applications.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line PanelView Plus 6 Compact

  • Part Number 2711PC-T10C4D1

  • Product Type PanelView Plus 6 Compact Terminal

  • Weight 6.00 lbs (2.72 kg)

  • Display Size 10.4 inches

  • Display Type Color active-matrix TFT

  • Display Area 211 × 158 mm (8.3 × 6.2 in.)

  • Resolution 640 × 480, 18-bit color graphics

  • Backlight CCFL, minimum 50,000 hours at 25 °C (field replaceable)

  • Operator Input Touchscreen (analog resistive)

  • Internal Flash Memory 25 MB

  • System Memory 512 MB nonvolatile memory and 512 MB RAM

  • Integrated Ports Ethernet, RS-232, 2 × USB host

  • Input Voltage Range 18–32 VDC

  • Nominal Input Power 24 VDC

  • Communication Options Ethernet and RS-232

  • Enclosure Rating NEMA/UL Type 12, 13, 4X (indoor use only), IEC IP54, IP65

  • Lifecycle Status End of Life

Application Scenarios

  • Operator interface for CompactLogix and MicroLogix systems

  • Machine-level visualization and control in manufacturing environments

  • Industrial HMI requiring Ethernet and RS-232 connectivity

  • Applications needing durable enclosures for indoor use with IP54/IP65 protection

FAQ

Q: What is the display lifespan?  A: The CCFL backlight is rated for at least 50,000 hours at 25 °C and can be replaced in the field.

Q: What communication ports are available?  A: The terminal includes Ethernet, RS-232, and two USB host ports.

Q: Is this model still in production?  A: No, the 2711PC-T10C4D1 has reached end-of-life status.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more