Skip to content

What are you looking for?


You may also like

Allen-Bradley 2711P-T4W22D8S PanelView Plus 7 Performance Touch TerminalAllen-Bradley 2711P-T4W22D8S PanelView Plus 7 Performance Touch TerminalAllen-Bradley 2711P-T4W22D8S PanelView Plus 7 Performance Touch Terminal
Allen-Bradley 2711P-T4W22D8S PanelView Plus 7 Performance Touch Terminal
Allen-Bradley 2711P-T4W22D8S PanelView Plus 7 Performance Touch Terminal
Allen-Bradley 2711P-T4W22D8S PanelView Plus 7 Performance Touch Terminal

Allen-Bradley 2711P-T4W22D8S PanelView Plus 7 Performance Touch Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T4W22D8S

PRODUCT TYPE : Touch Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 2711P-T4W22D8S serves as a high-performance operator interface within the PanelView Plus 7 Performance family. This 4.3-inch widescreen terminal provides advanced visualization for complex machinery and plant-wide control systems. It integrates seamlessly with Logix-based controllers, enabling real-time data monitoring and high-speed graphic rendering. We supply this unit as 100% Brand New original hardware, ensuring maximum system uptime and factory-standard response for your mission-critical HMI applications.

Technical Specifications

The 2711P-T4W22D8S utilizes a robust hardware architecture to handle intensive graphic processing:

Feature Specification
Display Type Color Active-Matrix TFT LCD (Widescreen)
Screen Size 4.3 inches (Diagonal)
Resolution 480 x 272 WQVGA (18-bit color)
Operator Input Analog Resistive Touch (1 million presses)
System Memory 512 MB RAM / 512 MB Non-volatile
Communication Dual (2) Ethernet Ports, Two (2) USB Ports
Input Voltage 24V DC (18-30V DC Range)
Power Consumption 35 W Max (1.46A at 24V DC)
Backlight Life 50,000 Hours (White Solid-State LED)
Shipping Weight 1.36 kg (3.00 lbs)

Engineering Advantages

  • Optimized Widescreen Visualization: The 16:9 aspect ratio increases usable display area compared to traditional small-format screens. This widescreen format allows engineers to group more status indicators and control objects onto a single page, reducing navigation depth.

  • Network Resilience with Dual Ethernet: Two onboard Ethernet ports support Linear, Star, and Device Level Ring (DLR) topologies. This redundancy ensures that the HMI maintains communication with the controller even if a physical network link breaks.

  • Industrial-Grade Touch Durability: The analog resistive touchscreen withstands up to 1 million actuations with a precise 100g operating force. This durability ensures the terminal remains responsive in environments where operators wear gloves or work in high-cycle production settings.

  • Non-Volatile Data Security: The 512 MB non-volatile memory stores complex application files and log data safely. Even during sudden power loss, the internal system prevents data corruption and ensures a rapid reboot to the operational state.

  • Compact Footprint for Narrow Enclosures: The 4.3-inch design fits perfectly into small control panels or machine-mounted enclosures where space is at a premium. Its efficient 24V DC power profile minimizes heat generation in confined spaces.

FAQs

Q: Can the 2711P-T4W22D8S support Device Level Ring (DLR) network topologies?

A: Yes. The two integrated Ethernet ports allow this Performance terminal to function as a node in a DLR network, providing superior network fault tolerance compared to standard single-port HMIs.

Q: Is the backlight replaceable if it fails?

A: No. The 2711P-T4W22D8S uses a solid-state white LED backlight designed for a minimum life of 50,000 hours. The internal construction does not support field replacement of the backlight module; however, the long-life LED typically outlasts the service cycle of the machine.

Q: How much free memory does the user have for HMI applications?

A: While the system features 512 MB of non-volatile memory, approximately 80 MB remains as dedicated free space for user application files (Runtime .mer files), ensuring ample room for detailed graphics and alarm histories.

Q: Does this model support external peripherals like keyboards or mice?

A: Yes. The terminal includes two high-speed USB ports that support external human interface devices (HID), allowing operators to use a mouse or keyboard for more complex data entry tasks when necessary.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more