Skip to content

What are you looking for?


You may also like

Allen Bradley 2711P-T10C4D9 PanelView Plus 6 Compact 1000 Touch TerminalAllen Bradley 2711P-T10C4D9 PanelView Plus 6 Compact 1000 Touch TerminalAllen Bradley 2711P-T10C4D9 PanelView Plus 6 Compact 1000 Touch Terminal
Allen Bradley 2711P-T10C4D9 PanelView Plus 6 Compact 1000 Touch Terminal
Allen Bradley 2711P-T10C4D9 PanelView Plus 6 Compact 1000 Touch Terminal
Allen Bradley 2711P-T10C4D9 PanelView Plus 6 Compact 1000 Touch Terminal

Allen Bradley 2711P-T10C4D9 PanelView Plus 6 Compact 1000 Touch Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T10C4D9

PRODUCT TYPE : Touch Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711P-T10C4D9 serves as a high-performance graphic interface within the PanelView Plus 6 Compact family. This 10.4-inch terminal enables operators to monitor, manage, and visualize complex industrial processes in real-time. It features a color active-matrix TFT display with resistive touch input, optimized for rugged factory floors. We supply this unit as 100% Brand New original stock, ensuring that your automation architecture maintains peak responsiveness and hardware longevity.

Technical Specifications

Feature Specification Details
Manufacturer Allen Bradley / Rockwell Automation
Display Size / Type 10.4-inch Color Active-Matrix TFT
Resolution 640 x 480 VGA
Operator Input Analog Resistive Touch (1 Million Actuations)
Input Power 18 to 32V DC (24V DC nominal)
Internal Memory 512 MB RAM / 512 MB Non-volatile
Backlight Life CCFL, 50,000 hours minimum (Field Replaceable)
Communication Ports 1 x Ethernet, 1 x RS-232, 1 x USB Host
Display Area 211 x 158 mm (8.3 x 6.2 in.)
Series A and B supported

Engineering Advantages

  • Efficient Memory Management: The 512 MB RAM and 512 MB non-volatile storage allow the 2711P-T10C4D9 to execute complex HMI applications with high-resolution graphics and extensive data logging. This hardware overhead prevents system lag during peak data processing cycles.

  • Flexible Communication Architecture: Integrated Ethernet and RS-232 ports allow this terminal to bridge communications between modern EtherNet/IP networks and legacy serial-based controllers. This dual-protocol capability simplifies system upgrades without requiring additional gateway hardware.

  • Field-Serviceable Design: The CCFL backlight carries a 50,000-hour lifespan rating and features a field-replaceable design. This allows maintenance teams to restore display brightness without replacing the entire HMI unit, significantly reducing long-term total cost of ownership (TCO).

  • Industrial Durability: The touchscreen supports over one million actuations, tolerating repetitive industrial use. Furthermore, the 18-32V DC power input range accommodates the typical fluctuations found in industrial DC power grids, protecting sensitive internal electronics from voltage transients.

FAQs

  • Can the 2711P-T10C4D9 replace older PanelView Plus models?

    Yes, the PanelView Plus 6 Compact series provides a migration path for legacy terminals. It utilizes FactoryTalk View Machine Edition software, allowing you to import existing .APA or .MER files to maintain operational continuity.

  • Which communication cable should I use for RS-232 connections?

    For standard serial communication between the terminal and a controller, use the 2711-NC13 cable. This ensures proper pin-out alignment and signal shielding against electromagnetic interference.

  • Is this unit compatible with USB peripherals?

    The integrated USB host port supports various external devices, including HID-compliant keyboards, mice, and flash drives for log file transfers. This feature enhances operator efficiency during initial system configuration or firmware updates.

  • How do I ensure the unit is Brand New?

    We ship the 2711P-T10C4D9 in its original, factory-sealed Allen Bradley packaging with the UPC 885630004204. Each unit carries a unique serial number that matches the manufacturer’s production records.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more