Product Details

Product Overview

The 2711P-RW1 functions as a dedicated internal Compact Flash memory module designed specifically for the Allen-Bradley PanelView Plus and PanelView Plus CE platforms. This 64 MB industrial-grade card provides the primary storage space for the FactoryTalk View Machine Edition (ME) runtime environment, application files, and operating system data. It installs directly into the logic module of the terminal to ensure high-speed data access during HMI boot-up and process visualization. We supply this unit as 100% Brand New and factory-original, guaranteeing the read/write endurance required for continuous industrial operation.

Technical Specifications

The 2711P-RW1 utilizes high-integrity flash architecture to withstand the rigorous power cycles of plant-floor environments.

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Storage Capacity 64 MB
Memory Type Compact Flash (Internal)
Compatibility PanelView Plus 400, 600, 700, 1000, 1250, 1500
Module Location Logic Module Internal Slot
Hardware Series Supports Series A through J
Power Consumption System Supplied
Weight 0.31 lbs (0.14 kg)

Engineering Advantages

  • Optimized Runtime Stability: The 2711P-RW1 stores the compiled HMI application, allowing for rapid loading of complex graphic displays and alarm logs. The industrial-grade flash controller prevents the data corruption often associated with consumer-grade storage cards.

  • Seamless Hardware Integration: This module fits perfectly into the dedicated internal slot of the PanelView Plus logic module. It requires no external power or cabling, maintaining the HMI’s compact form factor while providing essential non-volatile storage.

  • Vibration and Thermal Resistance: Unlike mechanical storage media, this solid-state module withstands the high-vibration environments typical of machine-mounted operator terminals. It operates reliably across the full temperature range specified for the PanelView Plus series.

  • Direct Legacy Support: For facilities maintaining older PanelView Plus hardware (Series A-J), the 2711P-RW1 provides the exact firmware-compatible storage needed to keep legacy terminals operational without the need for expensive system-wide upgrades.

FAQs

  • Does the 2711P-RW1 support Removal and Insertion Under Power (RIUP)?

    No. You must power down the terminal before installing or removing the 2711P-RW1. Performing this action while the unit is live risks permanent data loss or damage to the HMI logic module.

  • What tools do I need for installation?

    Installation requires standard #00, #1, or #2 Phillips screwdrivers to access the logic module. Most importantly, always wear an Electrostatic Discharge (ESD) wristband during installation to prevent static damage to the sensitive flash circuitry.

  • Can I use a standard off-the-shelf Compact Flash card instead?

    While standard cards may fit the slot, Rockwell Automation designs the 2711P-RW1 with specific industrial wear-leveling and timing parameters. Using non-approved cards often leads to "Module Not Found" errors or premature card failure during intensive data-logging tasks.

  • Is this card pre-loaded with firmware?

    This module serves as raw storage. You must transfer the appropriate PanelView Plus firmware and your specific application files using the FactoryTalk View ME Transfer Utility after installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more