Skip to content

What are you looking for?


You may also like

Allen Bradley 2711P-K7C4D1 PanelView Plus 700 Keypad HMI TerminalAllen Bradley 2711P-K7C4D1 PanelView Plus 700 Keypad HMI TerminalAllen Bradley 2711P-K7C4D1 PanelView Plus 700 Keypad HMI Terminal
Allen Bradley 2711P-K7C4D1 PanelView Plus 700 Keypad HMI Terminal
Allen Bradley 2711P-K7C4D1 PanelView Plus 700 Keypad HMI Terminal
Allen Bradley 2711P-K7C4D1 PanelView Plus 700 Keypad HMI Terminal

Allen Bradley 2711P-K7C4D1 PanelView Plus 700 Keypad HMI Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-K7C4D1

PRODUCT TYPE : HMI Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711P-K7C4D1 functions as a ruggedized operator interface for the PanelView Plus 700 system. This terminal features a 6.5-inch color active matrix display combined with a high-durability stainless steel keypad for precise command entry in demanding industrial environments. It facilitates high-speed data exchange across Ethernet and RS-232 networks, serving as the primary control hub for complex machinery. We supply this unit as 100% Brand New and Factory Original, ensuring zero-hour runtime and full component longevity for mission-critical applications.

Technical Specifications

The 2711P-K7C4D1 utilizes high-performance hardware to manage real-time graphical data and user inputs:

Feature Specification
Operator Input Keypad (22 Function Keys: F1–F10, K1–K12)
Display Type Color Active Matrix, Thin-Film Transistor (TFT)
Display Size 6.5-inch
Resolution 640 x 480 (VGA), 18-bit color graphics
Integrated Ports 1 Ethernet, 1 RS-232, 2 USB Host Ports
Input Voltage 18–32V DC (24V DC Nominal)
Onboard Memory 64 MB
Backlight Life 50,000-hour LED
Keypad Actuation 1 Million Presses
Weight 4.00 lbs (1.81 kg)

Engineering Advantages

  • Tactile Command Precision: The 22-key functional keypad provides definitive mechanical feedback. This eliminates the input errors common with touchscreens in environments where operators wear heavy gloves or where oil and debris contaminate the screen surface.

  • High-Fidelity Visualization: The 18-bit color TFT display delivers sharp 640 x 480 resolution. This allows for complex mimic diagrams and detailed alarm color-coding, which accelerates operator response times during critical process anomalies.

  • Dual-Network Architecture: The terminal integrates both Ethernet and RS-232 ports. This enables simultaneous communication with modern EtherNet/IP controllers and legacy serial devices, allowing the 2711P-K7C4D1 to act as a data bridge within heterogeneous factory floors.

  • Enhanced Memory Overhead: With 64 MB of integrated memory, the terminal handles large FactoryTalk View ME applications with ease. It manages extensive alarm logs, historical trending data, and high-resolution bitmap symbols without degrading system refresh rates.

  • Rugged Power Input: The wide 18–32V DC input range protects the internal logic from common voltage fluctuations found in heavy industrial DC buses. This ensures continuous HMI operation during high-current motor starts or power supply transients.

FAQs

  • Is this 2711P-K7C4D1 unit 100% Brand New?

    Yes. We guarantee this unit arrives in 100% Brand New condition, contained in its original factory-sealed packaging. This ensures you receive the maximum 50,000-hour backlight life and a pristine, unactuated keypad membrane.

  • Does this model support external peripherals?

    Yes. The two integrated USB host ports support external HID devices, including industrial mice and keyboards, as well as flash drives for rapid firmware updates or log file extraction.

  • How do I replace a failed 2711P-K7C4D1 without losing my application?

    Since we provide original factory hardware, you can simply transfer your application via a standard CompactFlash card or download the existing .MER file from FactoryTalk View Studio. The hardware remains 100% compatible with all previous series (A-G) project files.

  • Can this HMI operate in wash-down environments?

    When properly installed using the provided gasket and mounting clips, the 2711P-K7C4D1 maintains a NEMA 4X/IP65 rating (indoor use). This protects the internal electronics from low-pressure water jets and non-corrosive chemicals used in standard cleaning protocols.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more