Product Overview

The Allen Bradley 2711-T5A10L1 serves as a high-performance Human-Machine Interface (HMI) within the PanelView 550 Standard family. This terminal provides centralized visualization and touch-input control for machines integrated into DeviceNet networks. Although the manufacturer lists this series as discontinued, we supply this unit as 100% Brand New and Original, allowing maintenance teams to sustain legacy control architectures without the risk of refurbished hardware or the complexity of a full system migration.

Technical Specifications

The 2711-T5A10L1 utilizes a 5.5-inch display and robust communication ports to manage process data:

Feature Specification
Display Type Monochrome Blue-Mode LCD
Input Type Analog Touchscreen (128 Touch Pixels)
Display Size 5.5 in. (120 x 60 mm display area)
Resolution 256 x 128 Pixels
Communication DeviceNet Port; RS-232 Printer Port
Input Power 24V DC (18–32V DC range)
Application Memory 240 KB (Series E or later)
Operating Temp 0 to 55 °C (32 to 131 °F)
Real Time Clock Internal, Battery-Backed
Backlight Replacement 2711-NL1

Engineering Advantages

  • Optimized DeviceNet Integration: The integrated DeviceNet port facilitates high-speed data exchange with controllers and other field devices. This protocol reduces wiring complexity compared to traditional point-to-point I/O, streamlining the HMI’s connection to the broader industrial network.

  • Rugged Touch Interface: The analog resistive touchscreen provides a high-density 128-pixel touch grid. It allows operators to trigger commands with high precision, even while wearing industrial gloves, ensuring consistent performance in greasy or dusty plant environments.

  • Superior Screen Legality: The Monochrome Blue-Mode LCD features a 256 x 128 resolution. This high-contrast display ensures that operators can clearly read alarms and process variables across the 5.5-inch viewing area, even under harsh overhead factory lighting.

  • Maintenance-Free Clock Accuracy: An internal battery-backed real-time clock timestamps every alarm and data log entry. This ensures accurate forensic analysis of system events even following a total loss of primary 24V DC power.

  • Low Thermal Footprint: The terminal dissipates only 29 Watts (69 BTU/HR) during operation. This low heat output prevents the buildup of internal enclosure temperatures, protecting nearby PLC components and extending the lifespan of the HMI’s internal electronics.

FAQs

  • What is the primary function of the RS-232 port on this model?

    On the 2711-T5A10L1, the RS-232 port functions specifically as a printer port. It allows the terminal to output hard-copy alarm reports and data logs directly to a connected serial printer for record-keeping.

  • Can I replace the internal backlight if the screen dims?

    Yes. This model utilizes the 2711-NL1 replacement backlight. Replacing the backlight restores the original brightness of the monochrome display, effectively extending the service life of the unit.

  • Is this unit compatible with modern 24V DC industrial power?

    Yes. The terminal accepts an input range of 18–32V DC. It integrates seamlessly with standard 24V DC industrial power supplies common in modern control cabinets.

  • How do I ensure this "Discontinued" unit is actually new?

    We guarantee this unit is 100% Brand New. It remains in its original Allen Bradley factory-sealed packaging with all original security seals, labels, and the verifiable UPC (611320019506) intact.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more