Skip to content

What are you looking for?


You may also like

Allen Bradley 2711-T10C1L1 PanelView Standard 1000 Operator InterfaceAllen Bradley 2711-T10C1L1 PanelView Standard 1000 Operator InterfaceAllen Bradley 2711-T10C1L1 PanelView Standard 1000 Operator Interface
Allen Bradley 2711-T10C1L1 PanelView Standard 1000 Operator Interface
Allen Bradley 2711-T10C1L1 PanelView Standard 1000 Operator Interface
Allen Bradley 2711-T10C1L1 PanelView Standard 1000 Operator Interface

Allen Bradley 2711-T10C1L1 PanelView Standard 1000 Operator Interface


Only 10 left - Selling fast

PRODUCT SKU : 2711-T10C1L1

PRODUCT TYPE : Operator Interface

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711-T10C1L1 functions as a high-capacity Human-Machine Interface (HMI) within the PanelView Standard 1000 family. This terminal features a 10-inch color active-matrix display, providing operators with a clear, centralized visualization point for complex industrial processes. We supply this unit as 100% Brand New and Original, specifically designed for systems utilizing Remote I/O (RIO) communication. It serves as a direct hardware solution for maintaining legacy control architectures without the need for extensive software migration or panel redesign.

Technical Specifications

The 2711-T10C1L1 integrates high-resolution visualization with robust industrial networking:

Feature Specification
Display Type Color Active-Matrix TFT
Display Size 10.1 inches
Resolution 640 x 480 Pixels (VGA)
Operator Input Analog Resistive Touchscreen
Communication Ports Remote I/O (RIO) and RS-232
Input Voltage 24V DC (Nominal)
Power Range 18–32V DC
Weight 6.00 lbs (2.72 kg)
Category Operator Interface (HMI)

Engineering Advantages

  • Optimized Remote I/O Connectivity: The integrated RIO port facilitates seamless connection to PLC-5, SLC 500, and ControlLogix systems over long distances. This protocol supports high-speed deterministic data exchange, ensuring real-time status updates and command execution across the plant floor.

  • Responsive Touch Interface: The analog resistive touchscreen allows precise parameter entry and screen navigation. This interface withstands industrial conditions, responding accurately even when operators wear gloves or in environments prone to surface contaminants.

  • Large-Scale Visualization: The 10-inch color display offers a significant viewing area compared to smaller HMI models. This extra space allows engineers to design detailed process mimics, multi-state indicators, and complex alarm banners that remain legible from a distance.

  • Dual-Port Versatility: In addition to the RIO network, the built-in RS-232 port supports local printing or point-to-point communication. This secondary interface simplifies data logging and localized diagnostics without interrupting the primary network traffic.

  • Direct 24V DC Integration: The unit utilizes a standard 24V DC input, aligning with modern industrial power standards. This eliminates the need for high-voltage AC lines inside the operator console, enhancing safety and reducing electromagnetic interference (EMI) near sensitive electronics.

FAQs

  • Does this unit replace the older AC-powered PanelView models?

    Yes. If you are migrating from an AC-powered version, the 2711-T10C1L1 provides the same physical footprint and Remote I/O functionality but requires a 24V DC power source. Always verify your current power supply capacity before installation.

  • What is the primary function of the RS-232 port on this RIO model?

    The RS-232 port serves primarily as a printer port or for point-to-point file transfers. It does not replace the RIO port for controller communication but adds flexibility for generating hard-copy reports or localized monitoring.

  • Is this a refurbished unit since the series is discontinued?

    No. We guarantee this 2711-T10C1L1 is 100% Brand New and Original. It arrives in its original Allen Bradley factory-sealed packaging with all security seals, UPC labels, and documentation intact.

  • How do I configure the Remote I/O rack address?

    You configure the RIO station address and baud rate through the HMI's internal configuration menu or via the PanelBuilder32 software. Ensure the settings match the scanner's configuration in your PLC or SLC processor.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more