Skip to content

What are you looking for?


You may also like

Allen Bradley 2711-K5A20 PanelView 550 Standard Operator TerminalAllen Bradley 2711-K5A20 PanelView 550 Standard Operator TerminalAllen Bradley 2711-K5A20 PanelView 550 Standard Operator Terminal
Allen Bradley 2711-K5A20 PanelView 550 Standard Operator Terminal
Allen Bradley 2711-K5A20 PanelView 550 Standard Operator Terminal
Allen Bradley 2711-K5A20 PanelView 550 Standard Operator Terminal

Allen Bradley 2711-K5A20 PanelView 550 Standard Operator Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711-K5A20

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711-K5A20 serves as a specialized Human-Machine Interface (HMI) designed for high-performance machine-level visualization within the PanelView 550 Standard series. This terminal features a rugged tactile keypad and integrated Ethernet communication, providing a direct digital link to SLC 500, MicroLogix, and ControlLogix controllers. We supply this unit as 100% Brand New and Factory Original, offering a critical solution for facilities that must maintain validated legacy control systems without the high cost of a full panel redesign.

Technical Specifications

The 2711-K5A20 utilizes industrial-grade hardware to ensure data persistence and display clarity in factory environments:

Feature Specification
Operator Input Tactile Keypad (F1 through F10 Function Keys)
Display Type Monochrome LCD Blue Mode
Display Size 5.5-inch
Resolution 256 x 128 Pixels
Communication Ports Ethernet (EtherNet/IP) and RS-232 (Printer Port)
Input Voltage 100–240V AC
Frequency 50/60 Hz
Memory 170 KB Application Runtime
Backlight Replacement 2711-NL1
Weight 3.13 lbs (1.42 kg)

Engineering Advantages

  • Native Ethernet Connectivity: This terminal incorporates a built-in Ethernet port, enabling high-speed data transfer and seamless integration into plant-wide networks. It eliminates the need for external protocol converters and allows for remote diagnostics and centralized data collection.

  • Tactile Keypad Precision: The physical keypad provides definitive mechanical feedback, which ensures accurate command entry even when operators wear heavy protective gloves. This mechanical design prevents the accidental triggering often associated with touchscreens in high-vibration or electrically noisy environments.

  • Universal AC Power Input: The internal power supply accepts a wide range of 100–240V AC. This versatility allows for global installation without requiring localized voltage transformers, simplifying spare parts inventory for international manufacturers.

  • High-Contrast Blue Mode Display: The blue monochrome LCD delivers excellent visibility under varied lighting conditions. It maintains sharp text and icon clarity, ensuring operators can read critical alarms and process variables from multiple viewing angles.

  • Legacy Architecture Support: As a brand-new original unit, the 2711-K5A20 replaces failed obsolete hardware instantly. It allows maintenance teams to restore machine operation by simply moving the existing memory card or downloading the original PanelBuilder32 file.

FAQs

  • Is this 2711-K5A20 unit 100% Brand New?

    Yes. We guarantee this unit is 100% Brand New and ships in its original factory-sealed Allen Bradley packaging. We do not supply refurbished or used surplus, ensuring your facility receives hardware with its full original backlight and component lifespan.

  • Can I use the RS-232 port for controller communication?

    The RS-232 port on the 2711-K5A20 functions primarily as a printer port for alarm logs or as a download port. Primary controller communication occurs through the Ethernet port. If you require DH-485 or DH+ communication, you must select the appropriate 2711-K5A5 or 2711-K5A8 models.

  • What software do I need to program this terminal?

    You must use PanelBuilder32 software. The terminal supports application downloads directly over the Ethernet network or through a point-to-point RS-232 connection using a 2711-NC13 cable.

  • Does the unit come with mounting hardware?

    Yes. The factory-original unit includes the necessary mounting clips and the environmental sealing gasket to maintain the integrity of your enclosure's NEMA rating.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more