Skip to content

What are you looking for?


You may also like

Allen-Bradley 1797-PS2E2 FLEX Ex Intrinsically Safe Power SupplyAllen-Bradley 1797-PS2E2 FLEX Ex Intrinsically Safe Power SupplyAllen-Bradley 1797-PS2E2 FLEX Ex Intrinsically Safe Power Supply
Allen-Bradley 1797-PS2E2 FLEX Ex Intrinsically Safe Power Supply
Allen-Bradley 1797-PS2E2 FLEX Ex Intrinsically Safe Power Supply
Allen-Bradley 1797-PS2E2 FLEX Ex Intrinsically Safe Power Supply

Allen-Bradley 1797-PS2E2 FLEX Ex Intrinsically Safe Power Supply


Only 10 left - Selling fast

PRODUCT SKU : 1797-PS2E2

PRODUCT TYPE : Power Supply

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1797-PS2E2 serves as a specialized power supply engineered specifically for the FLEX Ex intrinsically safe I/O system. Designed for hazardous area applications, this unit accepts a standard 24V DC input and converts it into four independent, galvanically isolated 9.5V DC outputs. Each output channel delivers up to 8.5W of power, safely energizing intrinsically safe field instruments located within flame-proof or explosive environments. We supply this item as a 100% Brand New, factory-sealed unit.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley (Rockwell Automation)
Product Line FLEX Ex
Product Type Intrinsically Safe (IS) Power Supply
Input Voltage 24V DC (Operating Range: 12 - 32V DC)
Output Configuration Quad (4x) 9.5V DC Outputs
Output Power 4x 8.5W (Per channel)
Isolation IS Galvanically Isolated Outputs
Enclosure Rating Flame-proof / Hazardous Area Rated
Series Series A

Engineering Advantages

Quad-Channel Galvanic Isolation for Hazardous Areas
The 1797-PS2E2 provides four independent 9.5V DC outputs, each featuring robust galvanic isolation. This critical safety feature prevents dangerous energy from passing from the safe area to the hazardous area, protecting sensitive intrinsically safe sensors and transmitters. Engineers can power multiple field devices from a single module without worrying about ground loops or cross-channel interference.

Optimized Power for Intrinsically Safe Field Devices
Delivering 8.5W of power per channel, this supply is perfectly matched to the energy requirements of modern intrinsically safe instrumentation. The specialized 9.5V DC output ensures that field devices operate within their safe entity parameters, maintaining the integrity of the hazardous area classification while providing stable and consistent voltage.

Seamless FLEX Ex System Integration
Designed to mount directly onto the FLEX Ex bus, this power supply integrates effortlessly with other FLEX Ex I/O modules. Its compact, flame-proof enclosure design allows you to build dense, modular I/O racks for Zone 1 or Division 1 environments, significantly reducing panel space compared to traditional discrete safety barrier solutions.

FAQs

Q: What is the primary function of the 1797-PS2E2?
A: This module acts as a dedicated power supply for the Allen-Bradley FLEX Ex system. It takes a standard 12-32V DC input and provides four isolated 9.5V DC outputs specifically designed to safely power intrinsically safe devices in hazardous locations.

Q: How much power does each output channel provide?
A: Each of the four output channels delivers up to 8.5 watts of power. This capacity is sufficient to drive most standard intrinsically safe transmitters, sensors, and field instruments used in process automation.

Q: Why is galvanic isolation important in this power supply?
A: Galvanic isolation physically and electrically separates the input power from the output channels. In hazardous area applications, this prevents high-energy faults from reaching the field devices, ensuring the safety of the installation and preventing potential ignition sources.

Q: What input voltage range does this module accept?
A: The 1797-PS2E2 is designed for a nominal 24V DC input but operates reliably across a wide voltage range of 12 to 32V DC, accommodating various industrial control power supply configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more