Only 10 left - Selling fast

PRODUCT SKU : 1797-IE8NF

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1797-IE8NF functions as a high-precision interface for hazardous area instrumentation within the FLEX Ex I/O family. This module provides eight single-ended analog inputs designed specifically for mounting in Class I, II, III Division 1 & 2 locations. We supply this unit as 100% Brand New original factory stock. It features an integrated noise filter to ensure signal stability in high-interference environments, allowing for the direct connection of 4-20mA or 0-20mA field transmitters without the need for additional external barriers.

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Line FLEX Ex 1797
Number of Inputs 8 Single-ended, Non-isolated
Resolution 16 Bits
Hazardous Location Rating Class I, II, III Div 1 & 2; Groups A-G T4
Module Type Ex ib IIB/IIC T4 / AEx ib IIC T4
Integrated Noise Filter Included (Enhanced Signal Stability)
Step Response 4 Milliseconds
Power Dissipation 5.2 Watts
Field-side Power Consumption 7.5 Watts
Compatible Terminal Bases 1797-TB3 or 1797-TB3S
Keyswitch Position Position 3
Diagnostic Indicators 8 Red Fault LEDs, 1 Green Power LED

Engineering Advantages

  • Intrinsically Safe (IS) Design: The 1797-IE8NF eliminates the requirement for separate IS barriers or explosion-proof enclosures. The module's internal circuitry limits energy levels to prevent the ignition of flammable atmospheres, significantly reducing hardware costs and cabinet footprint in oil, gas, and chemical processing facilities.

  • Integrated Hardware Noise Filtering: The "NF" designation signifies advanced onboard filtering. This feature suppresses high-frequency electromagnetic interference (EMI) and crosstalk from nearby motor drives or power cables, providing clean 16-bit data to the controller in electrically noisy industrial environments.

  • Rapid Signal Processing: A 4 ms step response allows the module to capture fast-acting process variables. This low-latency performance ensures that the control system reacts instantly to pressure surges or flow fluctuations, maintaining tighter process loops and enhancing overall plant safety.

  • Comprehensive Fault Diagnostics: Eight dedicated red LEDs provide per-channel status monitoring. These indicators instantly alert technicians to wire-off conditions or sensor failures, facilitating rapid troubleshooting without the need to connect a laptop or open the control program.

  • High-Resolution Data Conversion: The 16-bit analog-to-digital converter transforms field signals into precise digital values. This granularity proves essential for applications requiring high accuracy, such as custody transfer or precision chemical dosing.

FAQs

  • Which terminal base must I use with the 1797-IE8NF?

    You must use the 1797-TB3 or 1797-TB3S terminal base. These bases provide the necessary termination points and physical mounting for the FLEX Ex module while maintaining IS circuit separation.

  • Does this module support HART communication?

    No. The 1797-IE8NF focuses on high-speed, filtered analog input processing. If your application requires HART protocol transparency for smart device diagnostics, you should consult the 1797-IE8H model.

  • What is the significance of Keyswitch Position 3?

    The keyswitch on the terminal base ensures that only the correct module type occupies the slot. Setting the base to Position 3 prevents accidental insertion of a different module type, which could otherwise compromise the intrinsic safety of the loop.

  • How do I verify the "Brand New" status of this unit?

    Every 1797-IE8NF arrives in its Original Factory-Sealed Packaging with the manufacturer's security label intact. As a new unit, the internal diagnostics register zero operation hours, and the gold backplane contacts remain free of any insertion marks, guaranteeing maximum service life in hazardous zones.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more