Skip to content

What are you looking for?


You may also like

Allen Bradley 1794-OF4IXT FLEX XT I/O Isolated Analog Output ModuleAllen Bradley 1794-OF4IXT FLEX XT I/O Isolated Analog Output ModuleAllen Bradley 1794-OF4IXT FLEX XT I/O Isolated Analog Output Module
Allen Bradley 1794-OF4IXT FLEX XT I/O Isolated Analog Output Module
Allen Bradley 1794-OF4IXT FLEX XT I/O Isolated Analog Output Module
Allen Bradley 1794-OF4IXT FLEX XT I/O Isolated Analog Output Module

Allen Bradley 1794-OF4IXT FLEX XT I/O Isolated Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1794-OF4IXT

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1794-OF4IXT functions as a high-precision analog output solution within the FLEX™ XT I/O family, engineered specifically for environments with extreme temperature fluctuations and electrical interference. This module provides four fully isolated channels that convert 15-bit digital data into precise current (4-20mA) or voltage (+/- 10V) signals. The "XT" designation signifies an extended temperature profile, while the "I" denotes channel-to-channel isolation. We provide this unit as 100% Brand New and Original, offering a robust interface for driving control valves, actuators, and motor drives in critical process applications.

Technical Specifications

The 1794-OF4IXT delivers superior signal modulation through the following technical parameters:

Feature Specification
Manufacturer Allen Bradley (Rockwell Automation)
Module Type Isolated Analog Output (FLEX XT)
Number of Outputs 4 Isolated Channels
Resolution 15 bits
Conversion Type Sigma Delta
Output Current 4–20 mA
Output Voltage +/- 10V
Isolation Voltage 120V Continuous
Update Rate 2.5 / 5.0 / 7.5 ms (Selectable)
FlexBus Current 50 mA
Thermal Dissipation 6.8 BTU/hr @ 31.2V DC max
Weight 0.25 lbs (0.11 kg)

Engineering Advantages

The 1794-OF4IXT addresses technical hurdles in distributed I/O and process regulation:

  • Superior Galvanic Isolation: The module features 120V continuous isolation between channels and from the backplane. This prevents ground loops and ensures that electrical noise or faults on one field device do not propagate to the other three channels or the central controller.

  • Extended Thermal Range (XT): Designed for extreme industrial conditions, the XT-rated components operate reliably in temperatures far exceeding standard I/O modules. This makes the 1794-OF4IXT ideal for outdoor remote terminal units (RTUs) or cabinets located near high-heat machinery.

  • High-Resolution Control: The 15-bit Sigma-Delta converter provides exceptional granularity for analog control. This allows for microscopic adjustments to valve positions or motor speeds, directly improving the efficiency and stability of your closed-loop control systems.

  • Rapid Update Capability: The selectable update rates (as fast as 2.5 ms) allow the module to respond to high-speed process changes. This reduces latency between the controller's logic execution and the physical response of the field equipment.

  • Low Thermal Signature: Despite its high-performance isolation and conversion, the module generates minimal heat (6.8 BTU/hr). This low power dissipation allows for high-density mounting in small enclosures without requiring additional cooling hardware.

FAQs

  • Does this module support both voltage and current outputs simultaneously?

    Yes. The 1794-OF4IXT provides dedicated terminals for both 4-20mA current and +/- 10V voltage. You configure the specific output type for each channel through your PLC programming software (such as Studio 5000).

  • What is the benefit of the Sigma Delta conversion in this module?

    Sigma Delta conversion provides high-accuracy oversampling and inherent noise filtering. It ensures that the digital-to-analog conversion remains stable and accurate even in electrically noisy environments typical of factory floors.

  • Which terminal bases are compatible with the 1794-OF4IXT?

    This module typically requires a 1794-TB3 or 1794-TBN terminal base. Ensure that your chosen terminal base and the accompanying I/O adapter are also rated for "XT" extended temperature operation to maintain system-wide environmental compliance.

  • How do I verify that this unit is brand new?

    Every 1794-OF4IXT unit we ship is 100% Brand New. We supply the hardware in original Allen Bradley factory-sealed packaging with authentic serial numbers and the UPC 612598592586 clearly displayed.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Upstream oil and gas operations rely on specialized field control platforms to manage wellhead extraction safety and hydraulic actuation. A Wellhead Control Panel (WHCP) serves as a dedicated hydraulic and pneumatic power unit designed to operate critical Christmas Tree isolation valves. By interfacing field safety components directly with Programmable Logic Controller (PLC) architecture, a WHCP protects upstream extraction assets against overpressure, catastrophic leaks, and thermal emergencies.

Read more
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more