Product Description

The Allen-Bradley 1794-IR8 is an eight-channel RTD input module designed for Flex I/O systems. It provides precise resistance temperature detector (RTD) measurement with high resolution and accuracy, supporting multiple terminal base units for flexible installation.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: Flex I/O

  • Part Number: 1794-IR8

  • Product Type: RTD Input Module

  • Number of Inputs: 8 channels

  • Module Location: Compatible with 1794-TB2, -TB3, -TB3S, -TB3T, -TB3TS terminal base units

  • Nominal Input Range: 1–433 ohms

  • RTD Excitation Current: 718.36 µA

  • Resolution: 16 bits across 435 ohms

  • Accuracy:

    • Normal mode: 0.05% full scale (max, without calibration)

    • Enhanced mode: 0.01% full scale (typical, low humidity)

  • Isolation Voltage: 850 V DC tested for 1 s (inputs and user power to logic side)

  • Data Format: 16-bit two’s complement or offset binary (unipolar)

  • Channel Bandwidth: 0–2.62 Hz (-3 dB)

  • Indicators: One red/green power status LED

  • Flexbus Current: 20 mA

  • Power Dissipation: 3.0 W max @ 31.2 V DC

  • Thermal Dissipation: 10.2 BTU/hr max @ 31.2 V DC

  • Weight: 1 kg

Features

  • Eight-channel RTD input capability for distributed temperature sensing

  • High accuracy with selectable normal and enhanced modes

  • Isolated channels for improved signal integrity

  • Compact Flex I/O design for modular installation

  • Diagnostic LED indicator for power status monitoring

Application Scenarios

  • Process Monitoring: Accurate RTD measurement for industrial temperature control

  • Distributed I/O Systems: Flexible integration with Flex I/O terminal bases

  • Legacy and Expansion Projects: Compatible with existing Flex I/O installations

FAQ

  • Q: How many input channels does the 1794-IR8 provide?  A: Eight RTD input channels.

  • Q: What terminal bases are supported?  A: 1794-TB2, -TB3, -TB3S, -TB3T, and -TB3TS.

  • Q: What is the accuracy of the module?  A: 0.05% full scale in normal mode, 0.01% typical in enhanced mode.

  • Q: Does the module provide isolation?  A: Yes, tested at 850 V DC for 1 second.

  • Q: How does this compare to the 1794-IR4?  A: The 1794-IR8 supports eight channels, while the 1794-IR4 provides four, making the IR8 suitable for higher-density applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more