Skip to content

What are you looking for?


You may also like

Allen Bradley 1794-IE8XT FLEX I/O Analog Input ModuleAllen Bradley 1794-IE8XT FLEX I/O Analog Input ModuleAllen Bradley 1794-IE8XT FLEX I/O Analog Input Module
Allen Bradley 1794-IE8XT FLEX I/O Analog Input Module
Allen Bradley 1794-IE8XT FLEX I/O Analog Input Module
Allen Bradley 1794-IE8XT FLEX I/O Analog Input Module

Allen Bradley 1794-IE8XT FLEX I/O Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1794-IE8XT

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1794-IE8XT functions as a high-density analog input solution within the FLEX I/O™ family, specifically engineered for "Extended Temperature" (XT) environments. This module interfaces between field sensors and your industrial controller, converting analog signals into digital data with high precision. We supply this unit as 100% brand new and original, ensuring maximum uptime in demanding industrial thermal conditions.

Technical Specifications

The table below highlights the performance-driven hardware specifications of the 1794-IE8XT:

Feature Specification
Number of Inputs 8 Single-ended, Non-isolated
Resolution (Voltage) 2.56 mV/cnt (Unipolar); 5.13 mV/cnt (Bipolar)
Resolution (Current) 5.13 µA/cnt
Conversion Method Successive Approximation
Module Type FLEX I/O Analog
Mounting Options DIN-rail or Panel Mount
Dimensions 5.33cm x 9.4cm x 4.57cm
Shipping Weight 3.0 kg

Engineering Advantages

  • Extended Thermal Resilience: The "XT" designation guarantees that this module withstands wider temperature fluctuations than standard I/O components. It eliminates the need for expensive enclosure cooling systems in harsh outdoor or high-heat manufacturing zones.

  • Space-Efficient Modular Design: The compact footprint (5.33cm x 9.4cm) allows for high-density I/O configurations. Engineers can snap the module onto a DIN rail or bolt it directly to a panel, providing flexibility in tight control cabinets.

  • Successive Approximation Conversion: This conversion technique ensures rapid and accurate data processing. The module digitizes analog signals with consistent timing, providing your PLC with the real-time feedback required for precise PID loops.

  • Simplified Wiring Integration: As a member of the FLEX I/O series, the 1794-IE8XT separates the I/O module from the terminal base. This allows you to wire the system and check for continuity before plugging in the electronics, preventing potential hardware damage during commissioning.

  • Versatile Signal Handling: The module supports both unipolar and bipolar voltage/current ranges. This versatility allows a single 1794-IE8XT to manage diverse sensors, from pressure transmitters to flow meters, reducing spare parts inventory.

FAQs

  • What is the difference between the 1794-IE8 and the 1794-IE8XT?

    The 1794-IE8XT features conformally coated circuitry and components rated for extended temperature ranges. While they share the same I/O count, the XT version provides superior durability in extreme environmental conditions.

  • Does this module require a separate terminal base?

    Yes. The 1794-IE8XT plugs into a 1794-TB3 or 1794-TB3S terminal base. You must secure the terminal base to the DIN rail before installing the module.

  • How does the 1794-IE8XT handle input isolation?

    This specific module utilizes non-isolated, single-ended inputs. All 8 channels share a common return. If your application requires channel-to-channel isolation, you should evaluate the 1794-IF4I or similar isolated modules.

  • Is this unit shipped in factory-sealed packaging?

    Absolutely. We ship only 100% brand new, original Allen Bradley stock. Every unit undergoes manufacturer quality control and arrives in original factory packaging to ensure E-E-A-T compliance and product longevity.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more