Allen-Bradley | 1756-L62 | ControlLogix 5560 | Programmable Automation ControllerAllen-Bradley | 1756-L62 | ControlLogix 5560 | Programmable Automation ControllerAllen-Bradley | 1756-L62 | ControlLogix 5560 | Programmable Automation Controller
Allen-Bradley | 1756-L62 | ControlLogix 5560 | Programmable Automation Controller
Allen-Bradley | 1756-L62 | ControlLogix 5560 | Programmable Automation Controller
Allen-Bradley | 1756-L62 | ControlLogix 5560 | Programmable Automation Controller

Allen-Bradley | 1756-L62 | ControlLogix 5560 | Programmable Automation Controller


Only 10 left - Selling fast

PRODUCT SKU : 1756-L62

PRODUCT TYPE : ControlLogix Controller

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1756-L62 ControlLogix 5560 Controller is a high-performance chassis-based module designed for complex automation systems. With 4 MB of user memory and robust I/O handling, it supports large-scale applications requiring precision, reliability, and scalability.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model: 1756-L62

  • Product Line: ControlLogix 5560 Series

  • Part Number: 1756-L62

  • User Memory: 4 MB

  • I/O Memory: 478 KB

  • Optional Nonvolatile Storage: 128 MB CompactFlash (1784-CF128)

  • Digital I/O Capacity (Max): 128,000 points

  • Analog I/O Capacity (Max): 4,000 points

  • Total I/O Capacity: 128,000 points

  • Replacement Battery Options:

    • Series A: 1756-BA1, 1756-BATM, 1756-BATA

    • Series B: 1756-BA2

  • Current Draw @ 5.1 VDC: 1200 mA

  • Current Draw @ 24 VDC: 14 mA

  • Power Dissipation: 3.5 W

  • Thermal Dissipation: 11.9 BTU/hr

  • Isolation Voltage: 30 V continuous, RS-232 to system (basic insulation type); type tested at 720 VDC for 60 seconds

  • Slot Width: 1

  • Module Location: Chassis-based, any slot

  • Wire Category: Category 2 (RS-232 port)

  • Temperature Code: T4A (North America)

  • Enclosure Rating: Open-style (no enclosure)

  • Weight: 0.50 lbs (0.23 kg)

Application Scenarios

  • Large-Scale Control Systems: Supports extensive digital and analog I/O for complex automation projects

  • Process Control: Provides reliable performance in manufacturing and energy applications

  • Motion and Safety Integration: Compatible with ControlLogix architecture for advanced system design

FAQ

  • Q: What type of nonvolatile memory is supported?  A: The 1756-L62 supports optional 128 MB CompactFlash (1784-CF128).

  • Q: Which batteries are compatible with this controller?  A: Series A uses 1756-BA1, 1756-BATM, 1756-BATA; Series B uses 1756-BA2.

  • Q: Can the module be installed in any chassis slot?  A: Yes, it is designed for installation in any available slot within a ControlLogix chassis.

  • Q: How does this model compare to the 1756-L63?  A: The 1756-L62 offers 4 MB user memory, while the 1756-L63 provides 8 MB, making the L63 more suitable for extremely large applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more