PRODUCT SKU : 1756-IR6I

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 1756-IR6I is a six-channel temperature-measuring analog module designed for Allen-Bradley ControlLogix systems. Each input is individually isolated, enabling precise and stable RTD measurements. This module supports high-resolution signal acquisition with advanced Sigma-Delta conversion and ensures long-term reliability under industrial environmental conditions.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model / Part Number: 1756-IR6I

  • Module Type: Temperature-Measuring Analog Input Module

  • Input Channels: 6 individually isolated RTD inputs

  • Input Range:

    • 1.87 Ω, 2.000 Ω, 4.000 Ω, 8.000 Ω

  • Resolution: 16-bit

    • 1.87 Ω: 7.7 mΩ/bit

    • 2.000 Ω: 15 mΩ/bit

    • 4.000 Ω: 30 mΩ/bit

    • 8.020 Ω: 60 mΩ/bit

  • Current Draw: 250 mA @ 5.1V, 125 mA @ 24V

  • Backplane Power: 4.25 W

  • Power Dissipation: 4.3 W max, Thermal dissipation 14.66 BTU/hr

  • Channel Bandwidth: 15 Hz

  • Settling Time: <80 ms to 5% full scale

  • Calibrated Accuracy (@ 25 °C): Better than 0.1% of range

  • Calibration Interval: 6 months

  • Offset Drift: 10 mΩ/°C

  • Gain Drift: Nominal 50 ppm/°C, Maximum 90 ppm/°C

  • Module Error: 0.54% of range

  • Module Scan Time:

    • 25 ms minimum (floating point, ohms)

    • 50 ms minimum (floating point, temperature)

    • 10 ms minimum (integer, ohms)

  • Data Format: Integer mode (left justified, 2’s complement) and IEEE 32-bit floating point

  • Conversion Method: Sigma-Delta

  • Isolation Voltage: 50 V continuous, tested 1350 V AC for 2 s

  • Module Keying: Electronic, software configurable

  • RTB Keying: User-defined mechanical

  • Slot Width: 1

  • Temperature Codes: North American T4A, IEC T4

  • Enclosure: Open-style

Application Notes

  • Designed for precise temperature measurement using RTD sensors

  • Compatible with Allen-Bradley ControlLogix systems

  • Ideal for process control, environmental monitoring, and industrial automation requiring high-resolution analog inputs

FAQ

Q: How many channels does the 1756-IR6I support?
A: Six individually isolated RTD inputs.

Q: What is the calibrated accuracy?
A: Better than 0.1% of full scale at 25 °C.

Q: Is the module isolated?
A: Yes, each input is isolated from the backplane and from other channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more