Skip to content

What are you looking for?


You may also like

Allen Bradley 1756-IN16 ControlLogix Digital AC Input ModuleAllen Bradley 1756-IN16 ControlLogix Digital AC Input ModuleAllen Bradley 1756-IN16 ControlLogix Digital AC Input Module
Allen Bradley 1756-IN16 ControlLogix Digital AC Input Module
Allen Bradley 1756-IN16 ControlLogix Digital AC Input Module
Allen Bradley 1756-IN16 ControlLogix Digital AC Input Module

Allen Bradley 1756-IN16 ControlLogix Digital AC Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IN16

PRODUCT TYPE : Digital AC Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1756-IN16 serves as a high-density discrete input interface for the ControlLogix platform. This module monitors and converts 24V AC signals from field devices—such as limit switches, pushbuttons, and proximity sensors—into logic levels usable by the controller. We supply this unit as 100% Brand New and Factory Original, ensuring peak electronic integrity and long-term stability in your automation rack.

Technical Specifications

The 1756-IN16 utilizes a robust circuit design to handle industrial AC voltage fluctuations:

Feature Specification
Number of Inputs 16 Individually Isolated Channels
Nominal Input Voltage 24V AC
Operating Voltage Range 10V to 30V AC
Nominal Frequency 50/60 Hz
Frequency Range 47 to 63 Hz
Operating Temperature 0°C to 60°C (32°F to 140°F)
Backplane Current (5.1V) 125 mA
Backplane Current (24V) 3 mA
Power Dissipation (Max) 5.1 W
Weight 0.70 lbs (0.32 kg)

Engineering Advantages

  • Broad Voltage Tolerance: The module accommodates an input range of 10V to 30V AC. This flexibility allows the hardware to function reliably despite line voltage drops or fluctuations common in large-scale industrial plants.

  • Integrated Noise Filtering: The 1756-IN16 incorporates onboard hardware filtering to reject high-frequency electrical noise. This prevents "nuisance" signals and false triggering caused by electromagnetic interference (EMI) from nearby motor starters or variable frequency drives.

  • Chassis-Based Diagnostic Support: The module utilizes the ControlLogix producer/consumer technology to report point-level status and fault data. This allows engineers to identify wiring issues or signal loss directly through the Studio 5000 environment without manual probing.

  • Simplified Field Wiring: This 16-point module optimizes space within the I/O rack. It utilizes a removable terminal block (RTB), which allows maintenance teams to replace the module without disconnecting individual field wires, significantly reducing Mean Time to Repair (MTTR).

FAQs

  • Is this 1756-IN16 unit 100% Brand New?

    Yes. We guarantee this product is 100% Brand New and arrives in its original factory packaging. It has never been installed or used in a production environment, ensuring full lifespan for its internal optical isolators.

  • Does the module require a specific Removable Terminal Block (RTB)?

    Yes. The 1756-IN16 requires either the 1756-TBNH or 1756-TBSH terminal block. You must order these separately as they do not come standard with the module itself.

  • Can I use this module for DC input signals?

    No. The 1756-IN16 is specifically designed for AC voltage. Using DC signals may result in improper state detection or damage to the internal bridge rectification circuitry. For DC applications, please refer to the 1756-IB16 or 1756-IV16.

  • How does the module handle signal debounce?

    The module features programmable input filter times. You can configure these settings in the controller software to match the mechanical characteristics of your field devices, effectively eliminating contact bounce issues.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more