Allen Bradley 1756-IF16IH ControlLogix 16-Channel HART Isolated Analog Input Module
Allen Bradley 1756-IF16IH ControlLogix 16-Channel HART Isolated Analog Input Module
Allen Bradley 1756-IF16IH ControlLogix 16-Channel HART Isolated Analog Input Module

Allen Bradley 1756-IF16IH ControlLogix 16-Channel HART Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IF16IH

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1756-IF16IH functions as a high-density, high-performance analog input solution within the ControlLogix® platform. This module provides 16 individually isolated channels and integrates HART (Highway Addressable Remote Transducer) data directly into the ControlLogix backplane. It allows users to capture sophisticated diagnostic data from "smart" field devices without requiring external hardware. We supply this unit as 100% brand new and original, ensuring maximum signal fidelity and system uptime for your critical process loops.

Technical Specifications

The 1756-IF16IH combines individual channel isolation with high-resolution data conversion:

Feature Specification
Number of Inputs 16 Individually Isolated Channels
Input Type Current (4–20 mA)
HART Support Integrated HART v5, v6, and v7
Resolution 16-bit
Backplane Current (5V) 250 mA
Backplane Current (24V) 125 mA
Isolation Voltage 250V (Continuous) Basic Isolation
Module Keying Electronic, Software Configurable
Mounting ControlLogix Chassis (Any Slot)
RTB Compatibility 1756-TBCH or 1756-TBSH

Engineering Advantages

  • Individual Channel Isolation: The 1756-IF16IH features point-to-point electrical isolation. This architecture prevents ground loops and ensures that an electrical fault on one field device does not compromise the signal integrity of the remaining 15 channels.

  • Integrated HART Diagnostics: The module acts as a HART modem for every channel. It passes secondary variables and device health status directly to the controller, enabling predictive maintenance strategies and remote instrument calibration via FactoryTalk® AssetCentre.

  • High-Density Monitoring: Providing 16 isolated channels in a single slot maximizes chassis space. This density reduces the number of I/O racks required for large-scale operations, lowering total system footprint and hardware costs.

  • Simplified Field Calibration: The 16-bit resolution provides extreme precision for sensitive process variables. This eliminates the need for frequent manual recalibration of the input loops, as the module maintains stable performance across varying industrial temperatures.

  • Hot-Swappable Design: Like all ControlLogix I/O, the 1756-IF16IH supports Removal and Insertion Under Power (RIUP). Maintenance teams can replace the module without shutting down the entire chassis, significantly reducing planned downtime.

FAQs

  • Does the 1756-IF16IH support voltage inputs?

    No. This module specifically optimizes for 4–20 mA current loops. If your application requires voltage inputs (0–10V), you should evaluate the 1756-IF16 or 1756-IF16V modules.

  • Is this a genuine, factory-sealed Allen Bradley original?

    Absolutely. We ship only 100% brand new 1756-IF16IH units in their original manufacturer packaging. Every module undergoes factory testing and arrives with a verified serial number for E-E-A-T procurement compliance.

  • Which Removable Terminal Block (RTB) does this module require?

    The module requires either the 1756-TBCH (36-pin Screw Clamp) or the 1756-TBSH (36-pin Spring Clamp) RTB. Please note that RTBs are sold separately and are essential for module operation.

  • Can I access HART data through the PLC ladder logic?

    Yes. The ControlLogix processor receives HART data as part of the module’s input image. You can use instruction sets to read device status, manufacturer IDs, and secondary process variables directly within Studio 5000®.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more