Only 10 left - Selling fast

PRODUCT SKU : 1756-EN27

PRODUCT TYPE : Ethernet Communication Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1756-EN2T is a high-speed Ethernet/IP communication module designed for the ControlLogix platform. It provides secure and reliable network connectivity with support for 10/100 Mbps communication rates. Compact and versatile, it fits into any ControlLogix chassis slot and offers both RJ45 and USB interfaces for flexible integration.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line ControlLogix

  • Product Type Ethernet Communication Module

  • Part Number 1756-EN2T

  • Weight 0.56 lbs (0.26 kg)

  • Communication Rate 10/100 Mbps Ethernet/IP

  • Integrated Ports 1 RJ45 Ethernet port, 1 USB 1.1 port

  • Insulation Voltage 30 V continuous

  • Current Draw 1 A

  • Current Rating 1.2 A

  • Power Dissipation 6.2 W

  • Thermal Dissipation 21.28 BTU/hr

  • Slot Width 1 (fits any ControlLogix chassis slot)

  • Operating Temperature Range 0–60 °C (32–140 °F)

  • Location ControlLogix chassis, any slot

Application Scenarios

  • High-speed Ethernet/IP communication for ControlLogix controllers

  • Integration of industrial devices into Ethernet-based networks

  • Applications requiring dual interface connectivity (Ethernet + USB)

  • Distributed control systems needing reliable communication modules

FAQ

Q: What communication speeds does the 1756-EN2T support?  A: It supports 10 Mbps and 100 Mbps Ethernet/IP communication rates.

Q: Can this module be installed in any ControlLogix chassis slot?  A: Yes, it is designed for installation in any available slot.

Q: What interfaces are available on the module?  A: It includes one RJ45 Ethernet port and one USB 1.1 port.

Comparison with Similar Models

  • 1756-ENBT: Earlier Ethernet/IP communication module with lower performance.

  • 1756-EN2T: Enhanced version with higher efficiency and dual interface support.

  • 1756-EN3TR: Advanced model with redundant Ethernet ports for fault-tolerant networks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more