Skip to content

What are you looking for?


You may also like

Allen-Bradley 1756-A4K ControlLogix 4-Slot Conformal Coated ChassisAllen-Bradley 1756-A4K ControlLogix 4-Slot Conformal Coated ChassisAllen-Bradley 1756-A4K ControlLogix 4-Slot Conformal Coated Chassis
Allen-Bradley 1756-A4K ControlLogix 4-Slot Conformal Coated Chassis
Allen-Bradley 1756-A4K ControlLogix 4-Slot Conformal Coated Chassis
Allen-Bradley 1756-A4K ControlLogix 4-Slot Conformal Coated Chassis

Allen-Bradley 1756-A4K ControlLogix 4-Slot Conformal Coated Chassis


Only 10 left - Selling fast

PRODUCT SKU : 1756-A4K

PRODUCT TYPE : PLC Chassis

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1756-A4K functions as the high-integrity foundation for compact ControlLogix control systems. This 4-slot back-panel mount chassis houses the processors, I/O modules, and communication cards required for industrial automation. We provide this unit as 100% Brand New and Original, ensuring peak performance for mission-critical logic control. By utilizing a "K" suffix designation, this specific model incorporates factory-applied conformal coating, providing an essential layer of protection against chemical contaminants and humidity.

Technical Specifications

Feature Specification
Number of Slots 4 Slots
Mounting Type Back Panel Mount
Power Dissipation 1.8 Watts
Operating Temperature 0°C to 60°C (32°F to 140°F)
Environmental Protection Conformal Coated (K-Version)
Net Weight 0.71 lbs (0.32 kg)
Series ControlLogix 1756

Engineering Advantages

  • Corrosion Resistance: The conformal coating shields internal circuitry from airborne pollutants, moisture, and salt spray. This feature prevents dendritic growth and premature board failure in wastewater treatment or chemical processing plants.

  • Thermal Efficiency: The chassis design optimizes airflow even in high-density enclosures. It maintains stable operation at temperatures up to 60°C, preventing thermal throttling of high-performance Logix processors.

  • Space-Saving Footprint: The 4-slot configuration allows engineers to deploy localized control nodes or remote I/O drops in cramped cabinets where larger 7, 10, or 17-slot racks cannot fit.

  • High-Speed Backplane: The 1756-A4K provides a high-speed communication bus that synchronizes data across all modules simultaneously. It eliminates bottlenecking in high-motion or rapid-response applications.

FAQs

  • What is the significance of the "K" at the end of 1756-A4K?

    The "K" signifies that the unit includes a factory-applied conformal coating. This makes the 1756-A4K superior to the standard 1756-A4 for environments involving corrosive gases or high humidity.

  • Does this chassis include the power supply?

    No. You must purchase the 1756 power supply (such as the 1756-PA72 or PB72) separately. The power supply mounts directly to the left side of the chassis without occupying any of the 4 functional I/O slots.

  • Can I mix conformal coated and non-coated modules in this chassis?

    Yes, the chassis accepts any standard 1756 ControlLogix module. However, to maintain the environmental integrity of the entire system in harsh conditions, we recommend using "K" version modules throughout the assembly.

  • Are the mounting dimensions different from the standard 1756-A4?

    No. The 1756-A4K maintains the exact physical dimensions and mounting hole patterns as the non-coated version, allowing for a direct "drop-in" replacement of existing hardware.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more