Skip to content

What are you looking for?


You may also like

Allen Bradley 1738-OE2CM12 ArmorPoint I/O 2-Channel Analog Output ModuleAllen Bradley 1738-OE2CM12 ArmorPoint I/O 2-Channel Analog Output ModuleAllen Bradley 1738-OE2CM12 ArmorPoint I/O 2-Channel Analog Output Module
Allen Bradley 1738-OE2CM12 ArmorPoint I/O 2-Channel Analog Output Module
Allen Bradley 1738-OE2CM12 ArmorPoint I/O 2-Channel Analog Output Module
Allen Bradley 1738-OE2CM12 ArmorPoint I/O 2-Channel Analog Output Module

Allen Bradley 1738-OE2CM12 ArmorPoint I/O 2-Channel Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1738-OE2CM12

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1738-OE2CM12 represents the pinnacle of "On-Machine" distributed I/O technology within the ArmorPoint® family. This 2-channel analog output module converts digital signals from the controller into precise analog variables to command actuators, valves, or motor drives. Designed for decentralized architectures, it eliminates the need for protective electrical cabinets by mounting directly onto machinery. We supply this module as 100% brand new and original, ensuring your high-pressure washdown environments benefit from factory-certified, sealed electronics.

Technical Specifications

The 1738-OE2CM12 utilizes a ruggedized form factor to maintain signal precision in extreme conditions:

Feature Specification
Number of Outputs 2 Single-ended
Connector Type M12 DC Micro Style
Enclosure Rating IP67, IP69K (Sealed)
Keyswitch Position 4
PointBus Current 75 mA
Power Consumption 1.0 W
Mounting On-Machine (No Enclosure Required)
Product Line ArmorPoint I/O
Net Weight 0.89 lbs (0.40 kg)

Engineering Advantages

  • IP69K Rated Protection: The fully sealed housing withstands high-pressure, high-temperature washdowns (up to 1450 psi and 80°C). This makes the 1738-OE2CM12 the ideal choice for food and beverage, pharmaceutical, and chemical processing lines where aggressive sanitation protocols occur daily.

  • Cabinet-Free Installation: This module mounts directly on the machine frame. This architecture slashes hardware costs by removing the need for large stainless steel enclosures and reduces the total wiring distance between the I/O and the final control element.

  • Standardized M12 Connectivity: The module utilizes industry-standard M12 micro-connectors. These threaded connections provide a secure, vibration-proof seal that prevents fluid ingress and ensures stable analog signal transmission even under heavy mechanical oscillation.

  • Simplified Mechanical Keying: The position 4 keyswitch ensures the module only seats into a correctly configured terminal base. This mechanical safety feature prevents the accidental installation of a digital module into an analog slot, protecting your I/O infrastructure from voltage mismatches.

  • Rapid Deployment & Maintenance: The ArmorPoint design allows for "Plug-and-Play" replacement. Technicians swap modules without disturbing field wiring, significantly reducing Mean Time to Repair (MTTR) during mission-critical production windows.

FAQs

  • What is the significance of the IP69K rating for this module?

    The IP69K rating certifies that the 1738-OE2CM12 resists the ingress of dust and high-pressure water jets from all angles. It remains functional in environments requiring frequent "Clean-In-Place" (CIP) procedures using hot water and chemical detergents.

  • Is this a genuine, brand-new Allen Bradley unit?

    Absolutely. We guarantee that every 1738-OE2CM12 we ship is 100% brand new in its original Allen Bradley packaging. Each unit satisfies all E-E-A-T procurement standards for authentic industrial hardware.

  • Does the 1738-OE2CM12 require a specific terminal base?

    Yes. You must mount the module onto an ArmorPoint terminal base, such as the 1738-TB3, which provides the mechanical support and the internal PointBus connection required for communication and power.

  • Can I monitor the status of the outputs locally?

    The module features integrated LED status indicators. These LEDs provide immediate visual diagnostics for network status and output health, allowing for rapid field inspections without specialized diagnostic tools.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more