Skip to content

What are you looking for?


You may also like

Allen Bradley 1734-IB8K POINT I/O 8-Point Sink Digital DC Input ModuleAllen Bradley 1734-IB8K POINT I/O 8-Point Sink Digital DC Input ModuleAllen Bradley 1734-IB8K POINT I/O 8-Point Sink Digital DC Input Module
Allen Bradley 1734-IB8K POINT I/O 8-Point Sink Digital DC Input Module
Allen Bradley 1734-IB8K POINT I/O 8-Point Sink Digital DC Input Module
Allen Bradley 1734-IB8K POINT I/O 8-Point Sink Digital DC Input Module

Allen Bradley 1734-IB8K POINT I/O 8-Point Sink Digital DC Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1734-IB8K

PRODUCT TYPE : Digital DC Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1734-IB8K operates as a high-density digital input module within the POINT I/O family. This module interfaces with field-side sensors and switches, converting 24V DC sinking signals into logic-level data for the controller. The "K" designation signifies a conformal coated build, providing superior resistance against environmental contaminants. We guarantee this unit as 100% Brand New original factory equipment, ready for immediate deployment in distributed I/O architectures.

Technical Specifications

Feature Specification Details
Manufacturer Allen Bradley / Rockwell Automation
Module Type Digital DC Input Module (Sinking)
Number of Inputs 8 Points
Voltage Category 24V DC
Environmental Protection Conformal Coated
Mounting DIN Rail (Horizontal or Vertical)
Enclosure Type Open Style (IP20)
Operating Voltage Range 10–28.8V DC
Weight 0.04 lbs (0.018 kg)

Engineering Advantages

  • Environmental Shielding: The conformal coating protects internal circuitry from moisture, salt spray, and corrosive chemical vapors. This hardware enhancement extends the service life of the module in wastewater treatment plants, oil rigs, and chemical processing facilities where standard modules often fail due to oxidation.

  • Granular Scalability: The ultra-compact POINT I/O footprint allows you to add I/O in increments of 8 points. This modularity reduces hardware waste and minimizes panel space requirements compared to traditional, bulkier PLC racks.

  • Simplified Troubleshooting: Bright LED indicators on the front housing provide instant visual feedback for module status and individual point activity. This feature allows maintenance teams to isolate wiring faults or sensor failures without connecting a laptop.

  • Rapid Installation: The module snaps directly onto the 1734-TB or 1734-TBS terminal base. This "Remove and Insertion Under Power" (RIUP) capability—when following proper safety protocols—shortens mean time to repair (MTTR) by allowing module swaps without dismantling the entire I/O stack.

FAQs

  • What is the difference between the 1734-IB8 and the 1734-IB8K?

    The 1734-IB8K includes a conformal coating on the internal PC board. Electrically, they function identically, but the "K" version offers necessary protection for harsh, humid, or corrosive industrial atmospheres.

  • Does this module require a specific terminal base?

    Yes. You must install the 1734-IB8K onto a 1734-TB, 1734-TBS, or 1734-TOP terminal base. Ensure you set the mechanical keying on the base to position 1 before inserting the module to prevent hardware damage.

  • Can I mix conformal coated and non-coated modules in the same rack?

    Yes, the POINT I/O backplane supports a mix of module types. However, for maximum system reliability in harsh environments, engineers typically specify conformal coating for all components within the cabinet.

  • Is this product factory sealed?

    Absolutely. We sell only 100% Brand New units in original Allen Bradley packaging. Each module includes the original factory seal, ensuring it has never been used or refurbished.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more