Skip to content

What are you looking for?


You may also like

Allen Bradley 1715 Redundant I/O 1715-OF8I 8-Channel Isolated Analog Output ModuleAllen Bradley 1715 Redundant I/O 1715-OF8I 8-Channel Isolated Analog Output ModuleAllen Bradley 1715 Redundant I/O 1715-OF8I 8-Channel Isolated Analog Output Module
Allen Bradley 1715 Redundant I/O 1715-OF8I 8-Channel Isolated Analog Output Module
Allen Bradley 1715 Redundant I/O 1715-OF8I 8-Channel Isolated Analog Output Module
Allen Bradley 1715 Redundant I/O 1715-OF8I 8-Channel Isolated Analog Output Module

Allen Bradley 1715 Redundant I/O 1715-OF8I 8-Channel Isolated Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1715-OF8I

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1715 Redundant I/O 1715-OF8I is an isolated analog output module designed for high-reliability process control applications. It provides eight independent channels with 4–20 mA output signals, ensuring accurate and stable performance in redundant I/O systems. With robust isolation, low power dissipation, and compatibility with 1715 terminal bases, this module is engineered for demanding industrial environments.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: 1715 Redundant I/O

  • Catalog Number / Model: 1715-OF8I

  • Category: PLCs / Analog Output Modules

  • Weight: 0.81 lbs (0.37 kg)

  • Module Type: 8-point isolated analog output

  • Channels: Eight isolated outputs

  • Operating Voltage Range: 18–32 VDC

  • Nominal Output Signal: 4–20 mA

  • Wire Size: 22–16 AWG

  • Wire Type: Shielded

  • Power Dissipation: 3.6 W max

  • Field Loop Power Dissipation: 0.64 W per loop

  • Isolation Voltage: 50 V continuous (basic insulation); tested at 500 V AC for 60 s

  • Module Base: 1715-A310

  • Terminal Base Assembly: 1715-TASOF8 or 1715-TADOF8

  • Enclosure Type: Open-style

Application Scenarios

  • Redundant control systems requiring isolated analog outputs

  • Process industries needing precise current loop control

  • Distributed I/O installations with high reliability requirements

FAQ

Q: How many analog outputs are supported?  A: Eight isolated channels.

Q: What is the supported output signal range?  A: 4–20 mA per channel.

Q: Which terminal bases are compatible with the 1715-OF8I?  A: 1715-TASOF8 and 1715-TADOF8.

Comparison with Similar Models

  • 1715-OF8I: 8 isolated analog outputs, 4–20 mA.

  • 1715-IF8I: 8 isolated analog inputs.

  • 1715-OB8: 8-channel digital output module.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more