Product Functionality

The 1485T-P2T5-T5 is a specialized DeviceNet PowerTap designed to inject 24V DC power into a DeviceNet network trunk line. This component is essential for large-scale industrial networks utilizing thick round cable media, ensuring that voltage levels remain stable across long distances and multiple nodes. It features a dual-port configuration that allows for seamless power distribution while maintaining the integrity of the data signals. By utilizing a terminal strip and cable gland design, the 1485T-P2T5-T5 provides a secure, industrial-grade connection point that prevents accidental disconnection and environmental contamination.

Technical Specifications

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Model Number: 1485T-P2T5-T5

  • Component Type: PowerTap (T-Port)

  • Network Compatibility: DeviceNet

  • Media Support: Thick Round Cable

  • Input Voltage: 24V DC

  • Current Rating: 15 Amps maximum

  • Port Configuration: 2-Port Output

  • Connection Method: Internal Terminal Strip with Cable Gland entry

  • Connector Keying: Standard Key Location

  • Enclosure Style: Sealed Industrial Housing

  • Physical Protection: Built-in fuse protection (depending on regional safety standards)

  • Installation: Inline mounting for trunk line power insertion

Network Integration and Use Case

In a standard DeviceNet architecture, the 1485T-P2T5-T5 serves as the primary junction where the external power supply meets the thick backbone cable. The use of thick media allows for higher current carrying capacity compared to thin media, making this PowerTap ideal for heavy-duty manufacturing environments. The internal terminal strip design is specifically chosen for high-vibration applications where M12 or M18 quick-disconnects might be insufficient. It ensures a low-resistance path for the 15A current, reducing voltage drop at the furthest ends of the network.

Frequently Asked Questions

Does the 1485T-P2T5-T5 support data termination?No, this module is strictly for power injection. A separate 121-ohm resistor must be placed at the physical ends of the trunk line for data signal termination.

Can I use this with Thin Round Cable?The 1485T-P2T5-T5 is specifically sized for thick round cable glands. While electrical connections are similar, the physical seal and cable strain relief are optimized for thick media (Thicknet).

What is the advantage of the 15A rating over standard taps?The 15 Amp capacity allows for a larger number of high-draw nodes (such as large solenoid valves or sensors) to be powered from a single injection point without overheating the conductors or causing significant voltage sag.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more