PRODUCT SKU : 440R-S13R2

PRODUCT TYPE : Safety Relay

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 440R-S13R2 serves as a core component of the Guardmaster Safety Relay (GSR) family, specifically the Single Function (CI) model. This module monitors safety-related circuits, including emergency stop push buttons, light curtains, and safety gates. It facilitates high-integrity safety functions in industrial machinery by managing power disconnection through its dedicated safety outputs. We provide this unit as 100% Brand New and factory-original, ensuring your safety architecture meets strict compliance standards without the risks associated with used hardware.

Technical Specifications

The 440R-S13R2 integrates high-density safety logic into a compact 22.5mm housing.

Feature Specification
Input Type 1 Dual Channel Universal (Legacy Compatible)
Safety Outputs 3 N.O. (Normally Open) Immediate
Auxiliary Output 1 N.C. (Normally Closed) Immediate
Safe Output 1 Single Wire Safe
Supply Voltage 24V DC
Reset Modes Automatic/Manual or Manual Monitored
Terminal Type Screw Terminals
Weight 0.40 lbs (0.18 kg)

Engineering Advantages

  • Universal Input Flexibility: The 440R-S13R2 accepts a wide range of inputs, from traditional dry contact switches to modern OSSD (Optical Output Signal Switching Device) inputs. This versatility allows engineers to standardize on a single relay model across diverse machine generations.

  • Single Wire Safety Connection: The integrated single-wire safety output enables the linking of multiple GSR relays using a single conductor. This reduces terminal wiring complexity and significantly shrinks the footprint required in crowded control cabinets.

  • Configurable Reset Logic: A simple rotary switch on the front face allows users to select between Automatic/Manual and Monitored Manual reset. This eliminates the need for complex software programming or additional external wiring for different safety protocols.

  • Narrow Profile Mounting: The slim 22.5mm DIN-rail design saves valuable rail space. This compact form factor solves the challenge of adding safety functionality to existing panels with limited expansion room.

FAQs

  • Is the 440R-S13R2 compatible with older Guardmaster safety devices?

    Yes. The module features "Legacy Compatible" inputs, specifically designed to interface with older safety switches and peripherals without requiring signal conversion.

  • What is the benefit of the "Manual Monitored" reset mode?

    Monitored reset prevents the system from restarting if the reset button remains stuck or is tied down. It requires the transition from depressed to released before energizing the safety outputs, adding an extra layer of operational safety.

  • Does this unit support expansion for more safety outputs?

    Yes. You can use the single-wire safety output to trigger additional expansion modules, allowing you to scale the number of safety contacts while maintaining the integrity of the original safety circuit.

  • Can I replace a standard relay with this module?

    This is a dedicated safety relay with internal redundancy and self-monitoring. You should use it to replace specific safety modules (like the older MSR series) or when upgrading a standard control circuit to meet SIL 3 or PLe safety ratings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more