Skip to content

What are you looking for?


You may also like

2711P-T4W21D8S | Allen-Bradley | PanelView Plus 7 Standard Operator Interface Terminal2711P-T4W21D8S | Allen-Bradley | PanelView Plus 7 Standard Operator Interface Terminal2711P-T4W21D8S | Allen-Bradley | PanelView Plus 7 Standard Operator Interface Terminal
2711P-T4W21D8S | Allen-Bradley | PanelView Plus 7 Standard Operator Interface Terminal
2711P-T4W21D8S | Allen-Bradley | PanelView Plus 7 Standard Operator Interface Terminal
2711P-T4W21D8S | Allen-Bradley | PanelView Plus 7 Standard Operator Interface Terminal

2711P-T4W21D8S | Allen-Bradley | PanelView Plus 7 Standard Operator Interface Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T4W21D8S

PRODUCT TYPE : Operator Interface Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 2711P-T4W21D8S serves as a high-resolution, widescreen operator interface within the PanelView Plus 7 Standard series. This terminal streamlines machine-level monitoring and control by providing a vibrant color graphic interface for complex industrial data. It utilizes the Windows CE 6.0 operating system to execute robust FactoryTalk View Machine Edition applications. We provide this unit as 100% Brand New and Original, ensuring your control system benefits from the latest hardware revisions and a pristine, factory-calibrated touchscreen.

Technical Specifications

Feature Specification Details
Display Size 4.3-inch Widescreen
Display Type Color Transmissive TFT
Resolution 480 x 272 WQVGA
Input Type Analog Resistive Touch
Operating System Windows CE 6.0
Input Voltage 24V DC (18–30V DC Range)
Communication Single 10/100 Ethernet Port
Aspect Ratio 16:9 Wide Aspect-Ratio
Weight 1.41 lbs (0.64 kg)

Engineering Advantages

  • Optimized Widescreen Visualization: The 16:9 aspect ratio provides more horizontal workspace compared to traditional 4:3 displays. This allows engineers to place alarm sidebars or navigation menus without obstructing the primary process graphic, improving operator situational awareness.

  • Simplified EtherNet/IP Connectivity: The integrated Ethernet port supports high-speed communication with Logix controllers. It facilitates rapid data synchronization and allows for remote diagnostics through FactoryTalk software, reducing the need for on-site physical inspections.

  • High-Density Installation: The compact 4.3-inch footprint enables installation in small control stations or directly on-machine where space remains at a premium. It replaces bulky push-button panels with a single digital interface, lowering hardware costs and enclosure size requirements.

  • Rugged Environmental Resilience: The resistive touchscreen survives contact with industrial contaminants, including oils, grease, and cleaning agents. It functions perfectly even when operated by staff wearing thick work gloves, ensuring consistent command input in harsh production environments.

FAQs

  • Can I replace an older PanelView Plus 6 400 with this model?

    The 2711P-T4W21D8S offers a modern widescreen alternative to the legacy 400 series. While the cutout dimensions differ due to the widescreen format, FactoryTalk View Studio handles the application migration, scaling your graphics to fit the higher 480 x 272 resolution.

  • Does this unit support SD cards for data logging?

    Yes. The terminal includes an SD card slot. You can use it to store historical trend data, log alarms, or perform rapid firmware updates and application backups without a computer connection.

  • What is the significance of the "Brand New" status for an HMI?

    HMI screens and backlights possess a finite operational life. By purchasing a 100% Brand New unit rather than a refurbished one, you guarantee maximum backlight brightness and touchscreen sensitivity, preventing "ghost touches" or display dimming common in used units.

  • Does this terminal require a specific power supply?

    The unit requires a 24V DC power source. We recommend using a Class 2 industrial-grade power supply to maintain the terminal's safety certifications and ensure stable voltage levels during motor startups on the same power bus.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more