PRODUCT SKU : 2711P-RP9D

PRODUCT TYPE : HMI Logic Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview of Functionality

The 2711P-RP9D is a high-performance processing engine designed specifically for the PanelView Plus 6 platform. This logic module serves as the primary computational component for 700, 1000, 1250, and 1500 series display terminals. It provides the necessary processing power, memory management, and communication interfaces required to run complex FactoryTalk View Machine Edition (ME) applications. By upgrading or replacing the base logic unit with the 2711P-RP9D, users benefit from enhanced system responsiveness and expanded memory capacity for demanding industrial HMI tasks.

Technical Characteristics

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Product Series: PanelView Plus 6

  • Model Component: 2711P-RP9D Logic Module

  • Processor Architecture: x86-based, 1.0 GHz

  • System RAM: 512 MB

  • Non-Volatile Flash Memory: 512 MB (Internal storage for applications and logs)

  • Operating System: Windows CE 6.0

  • Input Voltage: 24V DC

  • Maximum Power Dissipation: 70 Watts

  • Network Connectivity: Integrated 10/100 Mbps Ethernet port

  • Serial Interface: One RS-232 port (supports DF1 and DH-485 via adapter)

  • USB Ports: Two USB 2.0 Type-A host ports

  • Expansion Storage: SD card slot (secure digital) for external data management

  • Internal Expansion: One PCI slot (3.3/5V 32-bit) for optional communication modules

  • Diagnostics: Integrated Red and Green LED status indicators

  • Environmental Rating: Marine Certified for maritime applications

  • Weight: 0.91 kg (2.00 lbs)

Hardware Installation and Compatibility

The 2711P-RP9D is designed for rear-mounting on the display module of a PanelView Plus 6 terminal. It is compatible with the 700 through 1500 screen sizes, allowing for a standardized logic platform across different hardware footprints. The module includes a real-time clock (RTC) for timestamping critical alarm data and process variables. Its Marine Certification ensures high reliability in environments subject to vibration and atmospheric salt exposure, typical of offshore and maritime control systems

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more