Skip to content

What are you looking for?


You may also like

2711P-RN15C | PanelView Plus ControlNet Communication Module | Allen-Bradley2711P-RN15C | PanelView Plus ControlNet Communication Module | Allen-Bradley2711P-RN15C | PanelView Plus ControlNet Communication Module | Allen-Bradley
2711P-RN15C | PanelView Plus ControlNet Communication Module | Allen-Bradley
2711P-RN15C | PanelView Plus ControlNet Communication Module | Allen-Bradley
2711P-RN15C | PanelView Plus ControlNet Communication Module | Allen-Bradley

2711P-RN15C | PanelView Plus ControlNet Communication Module | Allen-Bradley


Only 10 left - Selling fast

PRODUCT SKU : 2711P-RN15C

PRODUCT TYPE : HMI Communication Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Module Overview

The 2711P-RN15C is a specialized ControlNet communication interface module designed for the Allen-Bradley PanelView Plus 400 and 600 terminal series. This module allows compact HMI terminals to integrate directly into a ControlNet network, enabling high-speed, deterministic data exchange with Logix5000 controllers. Although officially discontinued by the manufacturer in 2013, the 2711P-RN15C remains a vital component for maintaining legacy industrial networks where scheduled, repeatable communication is required for machine-level visualization.

Detailed Engineering Specifications

The 2711P-RN15C is a field-installable back-module that expands the connectivity of the smaller PanelView Plus units.

  • Module Type: ControlNet Communication Interface

  • Network Protocol: ControlNet (Coax)

  • Compatibility: PanelView Plus 400 and PanelView Plus 600 Terminals

  • Data Rate: 5 Mbps (Fixed ControlNet standard)

  • Connection Type: BNC (Coaxial)

  • Scheduled Messaging: Supports deterministic I/O and interlocking data

  • Unscheduled Messaging: Supports HMI display updates and trending

  • Firmware Support: Requires terminal firmware compatible with PV-400-600 series

  • Installation: Attaches to the back of the HMI base unit

  • Physical Weight: 0.31 lbs (0.14 kg)

  • Operating Temperature: 0°C to 55°C (32°F to 131°F)

Network Architecture and ControlNet Benefits

ControlNet is a "scheduled" network, meaning it guarantees that critical data is delivered at a specific, repeatable time interval. By adding the 2711P-RN15C to a PanelView Plus terminal, engineers can ensure that HMI pushbuttons and alarms are synchronized with the PLC scan. This is particularly important in high-speed coordinated motion or safety-monitoring applications where Ethernet latency might be unpredictable. The module supports both redundant and non-redundant media configurations depending on the terminal's physical port layout.

Installation and Maintenance

Since this module was discontinued over a decade ago, maintenance usually involves firmware management and physical connection integrity. The 2711P-RN15C must be firmly seated into the expansion slot on the rear of the PanelView Plus 400/600. Once installed, the terminal’s RSLinx Enterprise (FactoryTalk Linx) configuration must be updated to recognize the ControlNet node address, ensuring the HMI can browse the network and reference tags in the controller.

Technical FAQ

Can I use the 2711P-RN15C with a PanelView Plus 7 terminal?

No. The 2711P-RN15C is strictly designed for the legacy PanelView Plus 400 and 600 (Series A-F). PanelView Plus 7 terminals use different internal architectures and typically rely on EtherNet/IP for communication.

Does this module require a separate power supply?

No. The 2711P-RN15C draws all necessary power directly from the HMI terminal's internal expansion bus.

What is the maximum distance for a ControlNet segment using this module?

Using standard RG-6 coaxial cable, a segment can reach up to 1,000 meters (3,280 feet) without repeaters. If your HMI is located further away, ControlNet repeaters or fiber optic media converters would be required.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more