Product Overview

The Allen-Bradley 2711C-T6C functions as a streamlined, cost-effective visualization solution for standalone machines and localized control systems. This 6-inch PanelView Component terminal features a color transmissive CSTN passive matrix LCD with a 320 x 240 resolution. It offers integrated multi-vendor communication capabilities, allowing it to interface not only with Rockwell Automation controllers but also with third-party devices via Modbus and Siemens MPI protocols. We supply this unit as 100% Brand New and Original, ensuring your legacy panels continue to operate with full tactile precision and display clarity.

Technical Specifications

The 2711C-T6C integrates versatile connectivity into a compact, DC-powered industrial frame.

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Product Line: PanelView Component (Series C600)

  • Display Size: 6 inches (115 x 86 mm viewing area)

  • Display Type: Color CSTN Passive Matrix LCD

  • Resolution: 320 x 240 pixels

  • Operator Input: Analog Resistive Touch (1 million actuations)

  • Communication Ports: RS-232 (DH-485/DF1), RS-485, and USB Port

  • Input Voltage: 18–30V DC (24V DC nominal)

  • Backlight Life: 50,000 hours minimum

  • Heat Dissipation: 32 BTU per Hour

  • Weight: 2.06 lbs (0.94 kg)

Engineering Advantages

  • Universal Multi-Vendor Connectivity: Unlike many proprietary displays, the 2711C-T6C supports RS-485 and RS-232 protocols for Modbus and Siemens MPI. This allows engineers to consolidate data from diverse hardware brands onto a single operator station without requiring expensive protocol converters.

  • Software-Free Configuration: The terminal utilizes a built-in, browser-based configuration tool. By connecting a PC via the USB port, users design screens and configure tags through standard web browsers. This eliminates the need for locally installed software licenses and simplifies remote maintenance.

  • Rugged Touch Interface: The analog resistive touchscreen withstands the rigors of industrial environments. It carries a rating of 1 million presses, providing long-term responsiveness even in applications where operators frequently wear industrial gloves or work in high-vibration settings.

  • Seamless Legacy Replacement: As a discontinued model, finding brand new 2711C-T6C units is critical for maintaining existing machine footprints. This terminal fits precisely into original panel cutouts, preventing the need for costly metalwork modifications or complex HMI application migrations to newer platforms.

FAQs

  • Does the 2711C-T6C require specialized software for programming? No. You configure the terminal using its built-in dashboard via a web browser (optimized for Firefox or Internet Explorer). You simply connect the HMI to your PC via a USB cable or Ethernet (if applicable) to access the design environment.

  • Which protocols does the RS-232 port support? The RS-232 port supports DH-485 and DF1 protocols for direct connection to MicroLogix, SLC 500, and Micro800 controllers. It also facilitates serial communication with third-party Modbus RTU devices.

  • Is the backlight replaceable if it fails? The 50,000-hour backlight in the 2711C-T6C is not replaceable. When the backlight reaches its end-of-life, you must replace the terminal. Utilizing the screen-saver mode significantly extends the operational lifespan of the unit.

  • Can I transfer projects using a USB flash drive? Yes. The integrated USB port allows for rapid project uploads and downloads. This feature enables field technicians to update HMI applications on-site without needing a laptop or a direct network connection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more