Skip to content

What are you looking for?


You may also like

2711-K5A15 | Allen Bradley | PanelView Standard 550 Monochrome Terminal2711-K5A15 | Allen Bradley | PanelView Standard 550 Monochrome Terminal2711-K5A15 | Allen Bradley | PanelView Standard 550 Monochrome Terminal
2711-K5A15 | Allen Bradley | PanelView Standard 550 Monochrome Terminal
2711-K5A15 | Allen Bradley | PanelView Standard 550 Monochrome Terminal
2711-K5A15 | Allen Bradley | PanelView Standard 550 Monochrome Terminal

2711-K5A15 | Allen Bradley | PanelView Standard 550 Monochrome Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711-K5A15

PRODUCT TYPE : Monochrome Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711-K5A15 serves as a rugged, high-efficiency Human-Machine Interface (HMI) within the PanelView Standard 550 product line. This terminal provides critical machine-level monitoring and diagnostic capabilities for localized industrial applications. We supply this unit as 100% Brand New and Factory Original, offering a definitive solution for maintaining legacy systems without the risks associated with used or refurbished hardware.

Technical Specifications

The 2711-K5A15 combines a compact footprint with industrial-grade communication protocols:

Feature Specification
Display Type Monochrome Blue LCD
Display Size 5.5-Inch (Diagonal)
Resolution 256 x 128 Pixels
Input Method Stainless-Steel Domed Keypad
Communication Ports ControlNet and RS-232 (Printer Port)
Input Voltage 100–240V AC (50/60 Hz)
Firmware Support PanelBuilder32 Software
Unit Weight 2.58 lbs (1.17 kg)

Engineering Advantages

  • Native ControlNet Integration: This model features a built-in ControlNet port, enabling high-speed, deterministic data exchange between the HMI and the controller. It ensures real-time alarm updates and precise timing for synchronized industrial processes.

  • Rugged Keypad Durability: The industrial-grade keypad utilizes stainless-steel domes rated for millions of actuations. This physical input method excels in environments where moisture, oil, or debris render standard touchscreens unresponsive.

  • Wide-Range AC Power Supply: The internal power supply accepts a broad range of 100–240V AC. This allows for global installation flexibility and protects the electronics against fluctuating line voltages common in heavy-industrial zones.

  • Space-Saving Form Factor: The 5.5-inch design fits into narrow control cabinet doors where panel space remains at a premium. Despite its size, the high-contrast monochrome display maintains legibility under varied lighting conditions.

FAQs

  • Is this 2711-K5A15 unit genuinely new or "new-surplus"?

    We guarantee this unit is 100% Brand New. It arrives in its original manufacturer’s box with intact factory seals, ensuring you receive the highest component lifespan and reliability.

  • Does this model support ControlNet scheduled messaging?

    Yes. The 2711-K5A15 fully supports scheduled messaging on ControlNet networks, ensuring that high-priority control data arrives at the terminal with precise determinism.

  • Which software do I need to program this terminal?

    You must use PanelBuilder32 software to design and download applications to the 2711-K5A15. We recommend using the RS-232 port for direct configuration transfers from your engineering workstation.

  • Can the backlight be replaced in the field?

    The PanelView 550 series features a field-replaceable backlight. However, utilizing a Brand New unit ensures that the factory-installed backlight provides maximum brightness and MTBF (Mean Time Between Failures) from day one.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more