Product Overview

The Allen-Bradley 2085-IQ32T serves as a high-density expansion interface for the Micro850 and Micro870 programmable logic controller families. This module significantly expands the system capacity by providing 32 discrete input points in a single expansion slot. It supports both sinking and sourcing wiring configurations, offering maximum flexibility for interfacing with a wide range of industrial sensors and switches. We supply this unit as 100% Brand New and Original, ensuring your automation architecture utilizes factory-tested, high-reliability hardware with zero prior field cycles.

Technical Specifications

Parameter Specification Details
Input Points 32 Inputs
Operating Voltage Range 10V to 30V DC
Input Circuit Type 24V DC Sink/Source (also supports 24V AC)
On-State Current (Nominal) 5.2 mA @ 24V DC
Off-State Current (Max) 1.2 mA
Input Impedance (Max) 4.6 kΩ
Backplane Current Draw 190 mA @ 5V DC
Power Dissipation 7 Watts (Total)
Status Indicators 32 Yellow LED Indicators
Weight 0.50 lbs (0.23 kg)

Engineering Advantages

  • High-Density Space Optimization: The 2085-IQ32T packs 32 input channels into a slim form factor. This density allows for massive I/O expansion without requiring additional chassis or large enclosures, effectively solving the problem of limited DIN rail space in complex control panels.

  • Universal Input Versatility: The internal circuitry accommodates both 24V DC (Sink or Source) and 24V AC (50/60 Hz) signals. This flexibility enables engineers to consolidate different signal types onto a single module, reducing the overall bill of materials and simplifying inventory management.

  • Instantaneous Diagnostics: 32 dedicated yellow LED indicators provide real-time status for every input channel. Maintenance technicians can identify failed field devices or wiring breaks at a glance, bypassing the need for a laptop connection during initial hardware troubleshooting.

  • Rigid Backplane Integration: The module snaps securely onto the Micro800 expansion bus. This direct connection ensures high-speed data throughput and vibration resistance, preventing the intermittent signal drops often found in modular systems with weaker interlocking mechanisms.

FAQs

Q: Does the 2085-IQ32T require a separate terminal block?

A: Yes. High-density modules like the 2085-IQ32T typically utilize specific terminal block headers to manage the 32-point wiring. Ensure you select the correct compatible terminal block for the 2085 series to facilitate secure and organized field wiring.

Q: Can I use this module with a Micro820 controller?

A: No. The 2085-IQ32T expansion module only supports the Micro850 and Micro870 PLC families. The Micro820 uses 2080-series "Plug-in" modules that insert directly into the controller front, rather than the "Expansion" modules that mount to the right side of the CPU.

Q: Is this unit "New Surplus" or "Brand New"?

A: We guarantee this 2085-IQ32T is 100% Brand New and Original. It arrives in its original factory-sealed Allen-Bradley packaging. This ensures the optoisolators and internal semiconductors have never experienced thermal stress, providing the maximum possible service life for your application.

Q: What happens if the leakage current of my sensor exceeds 1.2 mA?

A: The module defines 1.2 mA as the maximum off-state current. If your sensor’s leakage current exceeds this value, the input may stay in the "ON" state erroneously. To prevent this, you must add a bleed resistor across the input to shunt the excess leakage current to ground.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more