Skip to content

What are you looking for?


You may also like

1794-OA16 Allen Bradley | FLEX I/O 16-Point AC Output Module1794-OA16 Allen Bradley | FLEX I/O 16-Point AC Output Module1794-OA16 Allen Bradley | FLEX I/O 16-Point AC Output Module
1794-OA16 Allen Bradley | FLEX I/O 16-Point AC Output Module
1794-OA16 Allen Bradley | FLEX I/O 16-Point AC Output Module
1794-OA16 Allen Bradley | FLEX I/O 16-Point AC Output Module

1794-OA16 Allen Bradley | FLEX I/O 16-Point AC Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1794-OA16

PRODUCT TYPE : AC Digital Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1794-OA16 is a FLEX I/O digital output module designed to provide 16 AC output points for distributed control systems. Built with an open-style enclosure for in-cabinet installation, it offers reliable switching of 120 V AC loads with minimal wiring requirements. This module is widely used in manufacturing, machine control, and process automation applications where modularity and compact design are essential.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line FLEX I/O 1794

  • Product Type AC Digital Output Module

  • Part Number 1794-OA16

  • Category I/O Modules

  • Subcategory FLEX I/O Digital Output Module

  • Weight 1.17 lbs (0.53 kg)

  • Outputs per Module 16 AC digital outputs

  • Voltage Rating 120 V AC

  • Output Current 500 mA per point, 4 A max per module

  • Enclosure Open-style (IP20)

  • Mounting Style DIN rail or panel mount

  • Terminal Style Screw-type connections

  • Operating Temperature 0–55 °C (32–131 °F)

  • Power Consumption 120 V AC supply

  • Certifications UL, CE, CSA, KC, C-Tick, GOST

  • Applications In-cabinet automation, distributed I/O systems

Application Scenarios

  • Switching AC loads in distributed FLEX I/O systems

  • Machine control applications requiring multiple AC outputs

  • Industrial automation panels with modular expansion needs

FAQ

Q: How many outputs does the 1794-OA16 provide?  A: It supports 16 AC digital output points.

Q: What is the maximum current per module?  A: Up to 4 A per module, with 500 mA per output point.

Q: What mounting options are available?  A: It can be mounted on DIN rails or panels.

Comparable Models

  • 1794-OA16: 16-point AC output module (this model)

  • 1794-OB16: 16-point DC transistor output module

  • 1794-OV16: 16-point DC sinking output module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more