Product Description

The Allen Bradley 1794-IJ2 is a FLEX I/O frequency input module designed to capture and process high-speed frequency signals in distributed control systems. It provides two isolated input channels with frequency and gate functionality, along with two isolated DC outputs. Supporting both sine and square wave inputs, the module ensures accurate measurement and reliable signal conversion for industrial automation applications.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line FLEX I/O 1794

  • Product Type Frequency Input Module

  • Part Number 1794-IJ2

  • Weight 0.50 lbs (0.23 kg)

  • Inputs 2 frequency inputs per channel (sine or square wave)

  • Input Frequency Range 1–32 kHz

  • Input Pulse Width 20 µs

  • On-State Voltage (Min) 10 V DC

  • On-State Current (Nom) 9.0 mA

  • Outputs 2 isolated DC outputs

  • Output Voltage Nominal 24 V DC, minimum 10 V DC

  • Output Current Max 1.0 A per channel

  • Output Off-State Voltage Max 31.2 V DC

  • Raw Frequency Value Up to 32,767 or 3,276.7 (depending on range)

  • External DC Supply Range 19.0–31.2 V DC (includes 5% AC ripple)

  • FlexBus Current 30 mA @ 5 V DC

  • Power Dissipation 4.6 W max @ 31.2 V DC

  • Thermal Dissipation 15.6 BTU/hr max @ 31.2 V DC

  • Terminal Base Compatibility 1794-TB3G or 1794-TB3GS

  • Mounting Style DIN rail

  • Wire Size Determined by installed terminal base

Application Scenarios

  • Frequency signal monitoring in distributed control systems

  • Machine control requiring precise frequency input and gated signal processing

  • Industrial automation environments with sine or square wave inputs

FAQ

Q: What frequency range does the 1794-IJ2 support?  A: It supports input frequencies from 1 to 32 kHz for both sine and square wave signals.

Q: How many outputs are available?  A: The module provides two isolated DC outputs.

Q: What terminal bases are compatible?  A: It can be used with 1794-TB3G or 1794-TB3GS terminal bases.

Comparable Models

  • 1794-IJ2: 2-channel frequency input module with isolated outputs (this model)

  • 1794-IF4I: 4-channel isolated analog input module

  • 1794-IB16: 16-point DC input module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more