Skip to content

What are you looking for?


You may also like

1794-IF4IXT Allen Bradley 4-Ch Isolated Analog Input XT1794-IF4IXT Allen Bradley 4-Ch Isolated Analog Input XT1794-IF4IXT Allen Bradley 4-Ch Isolated Analog Input XT
1794-IF4IXT Allen Bradley 4-Ch Isolated Analog Input XT
1794-IF4IXT Allen Bradley 4-Ch Isolated Analog Input XT
1794-IF4IXT Allen Bradley 4-Ch Isolated Analog Input XT

1794-IF4IXT Allen Bradley 4-Ch Isolated Analog Input XT


Only 10 left - Selling fast

PRODUCT SKU : 1794-IF4IXT

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1794-IF4IXT serves as a high-density, isolated analog input solution within the FLEX I/O XT family. This module interfaces directly with sensors in harsh industrial environments, converting 4-20mA or ±10V signals into precise 16-bit digital data. As a 100% Brand New original component, the "XT" designation signifies extended temperature and environmental hardening, ensuring stable performance where standard I/O modules fail.

Technical Specifications

The 1794-IF4IXT utilizes Sigma-Delta conversion technology to maintain high signal integrity across all channels.

Feature Specification
Number of Inputs 4 Isolated Channels
Resolution 16 Bits
Conversion Type Sigma Delta
Input Current Range 4–20 mA
Input Voltage Range ±10V
Isolation Voltage 120V Continuous
External DC Power 24V DC Nominal
FlexBus Current 50mA
Power Dissipation 2.0W @ 31.2V DC Max
Thermal Dissipation 6.8 BTU/hr @ 31.2V DC Max
Weight 0.31 lbs (0.14 kg)

Engineering Advantages

  • Eliminate Ground Loops: The 120V continuous isolation between channels prevents ground loop interference and protects the backplane from field-side electrical surges. This architecture ensures that a fault on one sensor does not compromise the entire I/O rack.

  • Extreme Temperature Resilience: The XT (Extended Temperature) rating allows the module to operate in outdoor cabinets and non-climate-controlled environments. It withstands thermal cycling and maintains 16-bit accuracy across its full operating range.

  • Precision Signal Processing: The Sigma-Delta converter filters out high-frequency industrial noise, providing clean, stable data for PID loops and sensitive flow-rate monitoring.

  • Space-Efficient Modular Design: The compact FLEX I/O footprint reduces cabinet space requirements. The module snaps directly onto a terminal base (1794-TB3 or 1794-TB3S), allowing technicians to wire the system before installing the electronics.

FAQs

  • What is the difference between the 1794-IF4I and the 1794-IF4IXT?

    The "XT" version features conformal coating and components rated for extended temperature ranges. While they share the same logical profile, the 1794-IF4IXT provides superior protection against humidity, salt spray, and extreme heat.

  • Does this module require a specific terminal base?

    Yes. Use the 1794-TBN, 1794-TB3, or 1794-TB3S terminal bases. We recommend the 1794-TB3S for applications requiring spring-clamp terminations in high-vibration areas.

  • Can I mix voltage and current signals on the same module?

    Yes. You can configure each of the four isolated channels independently to accept either a 4-20mA current signal or a ±10V voltage signal through software configuration in RSLogix 5000/Studio 5000.

  • Is this a Brand New unit?

    Yes. We supply only 100% Brand New original Allen Bradley factory-sealed hardware. Each unit includes the original manufacturer's UPC (612598592579).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more