1790D-T16BV0 Allen-Bradley CompactBlock LDX 16-Point Digital Input Module1790D-T16BV0 Allen-Bradley CompactBlock LDX 16-Point Digital Input Module1790D-T16BV0 Allen-Bradley CompactBlock LDX 16-Point Digital Input Module
1790D-T16BV0 Allen-Bradley CompactBlock LDX 16-Point Digital Input Module
1790D-T16BV0 Allen-Bradley CompactBlock LDX 16-Point Digital Input Module
1790D-T16BV0 Allen-Bradley CompactBlock LDX 16-Point Digital Input Module

1790D-T16BV0 Allen-Bradley CompactBlock LDX 16-Point Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1790D-T16BV0

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1790D-T16BV0 serves as a robust 16-point universal DC input block designed specifically for the CompactBlock LDX distributed I/O system. This device delivers exceptional wiring flexibility by supporting both sinking and sourcing configurations on its 24V DC inputs, allowing seamless integration with a wide variety of field sensors and switches. Engineered for harsh industrial environments, it withstands significant vibration and shock, making it ideal for machine-level automation applications. We supply this item as a 100% Brand New, factory-sealed unit.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley (Rockwell Automation)
Product Line CompactBlock LDX
Device Type Universal DC Input Base Block
Number of Inputs 16 Digital Inputs
Input Type 24V DC Sink / Source (Universal)
Nominal On-State Voltage 24V DC
On-State Voltage Range 9.6V DC (Min) to 28.8V DC (Max)
Off-State Voltage 5V DC (Max)
On-State Current 8 mA at 24V DC per Channel
Off-State Current 1.5 mA at 5V DC (Max)
Operating Temperature 0 to 60°C (32 to 140°F)
Operating Shock 30 g peak
Vibration 5 g at 10 to 500 Hz
Humidity 5 to 90% (Non-Condensing)
Weight 3.00 lbs (1.36 kg)

Engineering Advantages

Universal Sinking and Sourcing Flexibility
The 1790D-T16BV0 eliminates complex wiring workarounds by accepting both sinking and sourcing 24V DC signals on the same module. This universal input capability allows engineers to connect diverse field devices—such as PNP and NPN proximity sensors, limit switches, and pushbuttons—without needing separate modules for different sensor types, significantly simplifying inventory and panel design.

Ruggedized for High-Vibration Environments
Built to endure the physical demands of factory floor automation, this input block features a highly durable mechanical design. It withstands operating shock up to 30 g peak and continuous vibration of 5 g across a 10 to 500 Hz frequency range. This ruggedness ensures stable signal acquisition and prevents false triggers in dynamic applications like packaging machinery, conveyors, and automotive assembly lines.

Compact and Scalable Machine-Level I/O
As part of the CompactBlock LDX system, this module offers a space-saving footprint perfect for mounting directly on or near machinery. Its modular design allows you to daisy-chain multiple I/O blocks, reducing the amount of home-run wiring back to the main control cabinet and enabling faster, more cost-effective machine builds and retrofits.

FAQs

Q: Can the 1790D-T16BV0 handle both sinking and sourcing sensors?
A: Yes, this is a universal DC input block. It fully supports both sinking and sourcing 24V DC input configurations, giving you complete flexibility when integrating various field sensors and switches.

Q: What is the operating voltage range for the inputs to register an "On" state?
A: The module reliably detects an On-State when the input voltage is between 9.6V DC (minimum) and 28.8V DC (maximum), with a nominal rating of 24V DC.

Q: What I/O system is the 1790D-T16BV0 compatible with?
A: This input base block is designed exclusively for the Allen-Bradley CompactBlock LDX distributed I/O system, allowing for seamless expansion and integration with compatible network adapters.

Q: How much current does each input channel draw when active?
A: Each channel draws a maximum of 8 mA at 24V DC when in the On-State. Ensure your system power budget accounts for the total current draw of all active inputs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more