Product Description

The Allen-Bradley 1785-ME32 is a 32K word EEPROM memory module designed for PLC-5 controllers. It provides non-volatile program backup and storage, ensuring reliable operation in industrial automation systems. Compatible with standard PLC-5 processors, this module supports program retention and system recovery, making it essential for legacy PLC-5 installations.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line PLC-5

  • Product Type EEPROM Memory Module

  • Part Number 1785-ME32

  • Weight 0.19 lbs (0.09 kg)

  • Memory Size 32K words EEPROM

  • Function Program backup and storage

  • Compatibility Standard PLC-5 processors

  • Additional Memory 6K words SRAM

  • Backplane Requirement 2.5 A at 5 VDC

  • Maximum Analog I/O 3072 channels

  • I/O Scan Time per Rack

    • 10 ms at 57.6 kbit/s

    • 7 ms at 115.2 kbit/s

    • 3 ms at 230.4 kbit/s

  • Maximum I/O Chassis Supported

    • Total: 93

    • Extended Local: 0

    • Universal Remote: Up to 32 per I/O link

  • Communication Ports RS-232-C, RS-422-A, RS-423-A (1 port)

  • Expansion Control coprocessor expansion port available

Application Scenarios

  • Program backup for PLC-5 controllers in industrial automation

  • Legacy system support requiring EEPROM-based storage

  • Applications needing reliable non-volatile memory retention

  • Large-scale control systems with extensive I/O requirements

FAQ

Q: What is the memory size of the 1785-ME32?  A: It provides 32K words of EEPROM memory plus 6K words of SRAM.

Q: Which PLCs are compatible with this module?  A: It is designed for use with standard PLC-5 processors.

Q: What is the backplane current requirement?  A: 2.5 A at 5 VDC.

Comparison with Similar Models

  • 1785-ME16: 16K word EEPROM memory module.

  • 1785-ME32: 32K word EEPROM memory module for larger programs.

  • 1785-ME64: 64K word EEPROM memory module for extended applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more