Skip to content

What are you looking for?


You may also like

1785-ENET | Allen Bradley | PLC-5 EtherNet/IP Interface Module1785-ENET | Allen Bradley | PLC-5 EtherNet/IP Interface Module1785-ENET | Allen Bradley | PLC-5 EtherNet/IP Interface Module
1785-ENET | Allen Bradley | PLC-5 EtherNet/IP Interface Module
1785-ENET | Allen Bradley | PLC-5 EtherNet/IP Interface Module
1785-ENET | Allen Bradley | PLC-5 EtherNet/IP Interface Module

1785-ENET | Allen Bradley | PLC-5 EtherNet/IP Interface Module


Only 10 left - Selling fast

PRODUCT SKU : 1785-ENET

PRODUCT TYPE : Interface Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1785-ENET acts as a high-performance communication bridge, adding EtherNet/IP connectivity to existing PLC-5 control systems. This module enables legacy processors to exchange data with modern HMIs, SCADA systems, and other controllers over standard Ethernet networks. We supply this unit as 100% Brand New and Original, featuring a factory-applied conformal coating to ensure long-term durability in harsh industrial environments. By installing this module, you modernize your 1771-chassis based systems without a full processor replacement.

Technical Specifications

The 1785-ENET integrates directly into the PLC-5 architecture with the following parameters:

Feature Specification
Communication Protocol EtherNet/IP
Transmission Speed 10/100 Mbps (Auto-negotiating)
Port Interface One (1) RJ45 Ethernet Port
Backplane Current 1.0 A @ 5V DC
Power Dissipation 5 Watts
Heat Dissipation 17.06 BTU/hr
Status Indicators STAT, 10M, 100M LEDs
Environmental Protection Factory Conformal Coated
Max Modules per System 4
Weight 1.75 lbs (0.79 kg)

Engineering Advantages

  • Instant Modernization: This module provides an Ethernet port for "Classic" and "Enhanced" PLC-5 processors. It eliminates the reliance on slow DH+ or RIO networks, facilitating faster data throughput for modern plant-wide analytics.

  • Aggressive Environmental Resistance: The specialized conformal coating protects the internal circuitry from salt spray, high humidity, and airborne chemical contaminants. This treatment prevents short circuits and dendritic growth in corrosive atmosphere industries like wastewater or chemical processing.

  • Simplified Integration: The 1785-ENET connects directly to Channel 3 of the PLC-5 processor. This direct-connection architecture minimizes software configuration and does not require an external power supply, as the unit draws all necessary power from the 1771 backplane.

  • Deterministic Messaging: The module manages process messages efficiently, allowing the main CPU to focus on logic execution while the 1785-ENET handles the heavy communication overhead of the EtherNet/IP stack.

  • Flexible Diagnostics: Integrated LED indicators (STAT, 10M, 100M) provide real-time hardware and network health status. Technicians identify link speeds and diagnostic faults instantly without specialized software tools.

FAQs

  • Which PLC-5 series are compatible with the 1785-ENET?

    This module supports a wide range of processors, including Enhanced PLC-5/11, 5/20, 5/40, 5/60, and 5/80 models. Please verify your processor's hardware series and firmware revision (e.g., Series C Rev K or later) to ensure full compatibility.

  • Does this module require an external 24V DC power source?

    No. The 1785-ENET draws its 1.0 A of current directly from the 1771 backplane's 5V DC rail. Ensure your rack's power supply has sufficient headroom for this additional load.

  • What is the maximum number of Ethernet modules I can install in one rack?

    You can install up to four 1785-ENET modules in a single PLC-5 system. This allows you to segregate network traffic or create redundant communication paths to different plant sub-networks.

  • Is this a factory-sealed unit?

    Absolutely. We guarantee this 1785-ENET is 100% Brand New original stock. It arrives in factory-sealed Allen Bradley packaging with all original security seals and the verifiable UPC (612598169207) intact.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more