Product Overview

The Allen Bradley 1771-NR functions as a high-precision RTD (Resistance Temperature Detector) analog input module designed for the legacy PLC 5 architecture. It provides eight independent channels to interface directly with various industrial temperature sensors without requiring external signal transmitters. By converting low-level resistance signals into BCD or Natural Binary data, the 1771-NR enables the PLC 5 processor to monitor critical thermal variables in real-time. This module serves as a vital component for high-accuracy temperature sensing in chemical processing, power generation, and food manufacturing sectors.

Technical Specifications

Feature Detailed Specification
Manufacturer Allen Bradley / Rockwell Automation
Part Number 1771-NR
Module Type N-Series Analog I/O
Number of Inputs 8 RTD Inputs
Supported RTD Types 100Ω Platinum (385/3916), 120Ω Nickel, 10Ω Copper
Input Resolution 0.03° Celsius/bit; 0.06° Fahrenheit/bit
Resistance Range 1 to 650 Ohms
Data Format BCD (Binary Coded Decimal) or Natural Binary
Backplane Current 1.5 Amperes
Remote Terminal Panel 1771-RTP4
Wiring Arm 1771-WH
Condition 100% Brand New Original

Engineering Advantages

  • Direct Sensor Interfacing: The 1771-NR eliminates the need for expensive and bulky temperature transmitters. It accepts raw resistance signals from Platinum, Nickel, and Copper RTDs directly, reducing the total bill of materials (BOM) and simplifying the electrical loop architecture.

  • High Thermal Resolution: This module delivers a resolution of 0.03°C per bit. This level of sensitivity allows the PLC 5 system to detect minute temperature fluctuations, ensuring tighter process control and preventing thermal runaway in sensitive chemical reactions.

  • Flexible Data Formatting: The hardware supports both BCD and Natural Binary data formats. Engineers can select the format that matches their existing PLC 5 logic structure, which streamlines software integration and avoids complex data conversion routines.

  • Robust Signal Integrity: Built-in signal delays (45-50 ms) filter out high-frequency industrial noise. This feature ensures that the processor receives stable and repeatable temperature data even when the module resides in cabinets near large motor drives or high-voltage switchgear.

  • Standardized Rack Integration: The 1771-NR slots into any standard 1771 I/O chassis. It utilizes the 1771-WH wiring arm, which allows maintenance personnel to replace modules without disconnecting field wires, significantly reducing Mean Time to Repair (MTTR).

FAQs

  • Is this 1771-NR unit 100% Brand New?

    Yes. We supply this 1771-NR module in 100% Brand New, original factory condition. Despite the legacy status of the PLC 5 line, we provide original, unused hardware to ensure the highest reliability for your critical infrastructure.

  • Which Platinum RTD standards does this module support?

    The 1771-NR supports both the European standard (coefficient 0.00385) and the U.S. standard (coefficient 0.003916). You must configure the module via the PLC software to match the specific sensor type installed in the field.

  • Do I need a specific terminal panel for high-density wiring?

    Yes. For optimal cable management and signal shielding, we recommend using the 1771-RTP4 Remote Terminal Panel. This simplifies the connection of the eight RTD sensors to the 1771-NR module.

  • Can the 1771-NR monitor resistance values other than temperature?

    The module can operate in an Ohms-only mode with a range of 1 to 650 Ohms. This allows it to monitor potentiometers or other resistance-based feedback devices alongside standard RTD sensors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more