Product Details

Overview
The 1769-IF4XOF2 is an Allen-Bradley CompactLogix module designed for combined analog input and output control. It integrates four analog inputs and two analog outputs in a single, compact module, providing reliable performance for small to medium-scale automation systems.

Technical Specifications

  • Brand & Model: Allen-Bradley 1769-IF4XOF2

  • Product Line: CompactLogix

  • Product Type: Combination Analog Input/Output Module

  • I/O Points: 4 analog inputs, 2 analog outputs

  • Input Voltage Range: 0–10 VDC

  • Output Current Range: 0–20 mA

  • Resolution: 8-bit

  • Mounting: DIN rail or panel mount

  • Enclosure Style: Open-style

  • Weight: 1.0 lbs (0.45 kg)

  • Module Family: CompactLogix

Features

  • Supports mixed analog input/output within a single module

  • Compact design reduces panel space requirements

  • High reliability with consistent signal conversion

  • Easy integration with other CompactLogix 1769 modules

Applications
Suitable for process control, machine automation, data acquisition, and distributed control systems where compact analog I/O solutions are required.

FAQ

Q: How many analog inputs and outputs does the 1769-IF4XOF2 provide?
A: The module offers 4 analog inputs and 2 analog outputs.

Q: Can this module be mounted on both DIN rails and panels?
A: Yes, it supports both DIN rail and panel mounting for flexible installation.

Q: What is the voltage range for analog inputs?

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more