Skip to content

What are you looking for?


You may also like

1762-IF2OF2 | Allen-Bradley MicroLogix | 4-Channel Analog Combination I/O Module1762-IF2OF2 | Allen-Bradley MicroLogix | 4-Channel Analog Combination I/O Module1762-IF2OF2 | Allen-Bradley MicroLogix | 4-Channel Analog Combination I/O Module
1762-IF2OF2 | Allen-Bradley MicroLogix | 4-Channel Analog Combination I/O Module
1762-IF2OF2 | Allen-Bradley MicroLogix | 4-Channel Analog Combination I/O Module
1762-IF2OF2 | Allen-Bradley MicroLogix | 4-Channel Analog Combination I/O Module

1762-IF2OF2 | Allen-Bradley MicroLogix | 4-Channel Analog Combination I/O Module


Only 10 left - Selling fast

PRODUCT SKU : 1769-IF2OF2

PRODUCT TYPE : Analog Combination Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Module Overview

The 1762-IF2OF2 is a compact, high-efficiency analog combination module designed for the Allen-Bradley MicroLogix 1100, 1200, and 1400 controller series. By providing two differential input channels and two single-ended output channels in a single-slot housing, it offers a cost-effective solution for small-scale PID loop control and process monitoring. This module is engineered to interface with a broad spectrum of industrial instrumentation, including pressure transmitters, flow meters, and variable frequency drives (VFDs), ensuring high-fidelity signal conversion in space-constrained control panels.

Detailed Engineering Specifications

The 1762-IF2OF2 features 12-bit monotonic resolution, providing 4,096 discrete counts to represent the full range of the analog signal.

  • I/O Configuration: 2 Differential Inputs / 2 Single-Ended Outputs

  • Input Signal Ranges: 0 to 10V DC and 4 to 20 mA

  • Output Signal Ranges: 0 to 10V DC and 4 to 20 mA

  • Resolution: 12-Bit Unipolar

  • Data Formats: Raw/Proportional (0–31,208) and Scaled-for-PID (0–16,383)

  • Backplane Current Draw: 40 mA at 5V DC / 105 mA at 24V DC

  • Input Impedance: 200 kΩ (Voltage) / 250 Ω (Current)

  • Output Load Capability: > 1 kΩ (Voltage) / < 500 Ω (Current)

  • Frequency Response: 500 Hz Digital Filter

  • Overall Accuracy: ±0.5% of Full Scale (Inputs) / ±1.0% of Full Scale (Outputs)

  • Operating Temperature: -20°C to 65°C (-4°F to 149°F)

  • Hazardous Location Rating: Class I, Division 2, Groups A, B, C, D

  • Physical Weight: 0.52 lbs (0.24 kg)

Advanced Diagnostics and Reliability

To ensure system integrity, the 1762-IF2OF2 includes onboard diagnostic bit reporting. The module monitors for "Over-Range" and "Under-Range" conditions, immediately notifying the MicroLogix CPU if a field signal falls outside the calibrated 4–20mA or 0–10V window. This is particularly vital for detecting sensor failures or broken wire conditions in critical feedback loops. Additionally, the module features high-voltage isolation between the field-side signals and the logic-side backplane, protecting the PLC processor from external electrical transients.

Installation and Hardware Integration

The 1762-IF2OF2 is designed for easy DIN rail mounting and includes a removable terminal block (RTB) for simplified wiring. For current-loop applications, the module utilizes internal 250-ohm precision resistors; however, it is important to note that the module does not provide loop power. An external 24V DC power supply must be wired in series with the transmitter and the module inputs. During installation, proper grounding of the cable shields to the PLC's chassis ground is required to maintain the 12-bit signal accuracy in noisy industrial environments.

Technical FAQ

Can I use one channel for Voltage and another for Current simultaneously?

Yes. Each input and output channel is individually wired and configured. You can monitor a 0–10V pressure transducer on Input 0 while driving a 4–20mA VFD command on Output 0.

Is this module compatible with the MicroLogix 1500?

Yes. While the 1762-IF2OF2 is the primary expansion for the MicroLogix 1100, 1200, and 1400, it is also fully compatible with the 1764-based MicroLogix 1500 platform using the 1762 expansion bus.

Does the module require software calibration?

The 1762-IF2OF2 is factory-calibrated. However, in RSLogix 500 or CCW software, you must select the correct "Data Format" (Raw/Proportional vs. Scaled-for-PID) to ensure the PLC registers match your logic requirements.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more