Skip to content

What are you looking for?


You may also like

1756-M2 | Allen Bradley | ControlLogix 1 MB Expansion Memory Module1756-M2 | Allen Bradley | ControlLogix 1 MB Expansion Memory Module1756-M2 | Allen Bradley | ControlLogix 1 MB Expansion Memory Module
1756-M2 | Allen Bradley | ControlLogix 1 MB Expansion Memory Module
1756-M2 | Allen Bradley | ControlLogix 1 MB Expansion Memory Module
1756-M2 | Allen Bradley | ControlLogix 1 MB Expansion Memory Module

1756-M2 | Allen Bradley | ControlLogix 1 MB Expansion Memory Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-M2

PRODUCT TYPE : Memory Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1756-M2 serves as a specialized expansion memory module designed specifically for the first-generation ControlLogix® controller platform. This module provides 1 MB of additional user memory to support larger program logic, increased tag storage, and more complex data arrays. While the manufacturer has discontinued the 1756-M2, it remains a critical component for facilities running legacy Logix5550™ systems that require a memory boost without a complete processor migration. We supply this unit as 100% brand new and original, ensuring maximum data integrity for your existing automation architecture.

Technical Specifications

The 1756-M2 integrates directly into compatible 1756-series processors to expand operational capacity:

Feature Specification
Memory Capacity 1 Mbyte Words
Module Type Expansion Memory (SRAM)
Compatible Controllers 1756-L1, 1756-L1M1, 1756-L1M2, 1756-L1M3
Product Line ControlLogix / Logix5550
Category PLC Module / Rack
Net Weight 0.75 lbs (0.34 kg)
Mounting Internal Processor Slot

Engineering Advantages

  • Seamless Logic Expansion: The 1756-M2 instantly increases the available user memory for legacy L1-series processors. This allows engineers to download larger ladder logic routines and expanded function block structures to aging hardware that would otherwise reach its capacity limit.

  • Preserves Legacy Infrastructure: Installing this expansion module eliminates the need for expensive and time-consuming controller upgrades. It provides a mechanical and fiscal solution for keeping proven automation lines running efficiently.

  • Direct Hardware Integration: The module fits securely into the dedicated memory expansion slot on the front of the 1756-L1 series controllers. This internal mounting maintains the original footprint of the CPU within the ControlLogix chassis.

  • High-Speed Data Access: The 1756-M2 utilizes high-speed static RAM to ensure the processor maintains its original scan rates. Adding this memory does not compromise the deterministic performance of the Logix5550 engine.

  • Reliable Data Retention: When used with the controller’s standard battery, the 1756-M2 retains stored programs and tag values during power cycles, preventing data loss and ensuring immediate machine recovery upon restart.

FAQs

  • Which specific controllers support the 1756-M2 expansion?

    This module only works with early-generation ControlLogix processors, specifically the 1756-L1 and its sub-models (L1M1, L1M2, L1M3). Newer processors, such as the 1756-L6 or L7 series, utilize built-in memory or different SD-card architectures and do not support the 1756-M2.

  • Is this a genuine, brand-new unit since the module is discontinued?

    Yes. We guarantee the 1756-M2 as 100% brand new and original. We source these from factory-sealed stocks to ensure you receive a unit with zero previous runtime, meeting all E-E-A-T procurement standards for mission-critical industrial spares.

  • Does the installation of the 1756-M2 require software configuration?

    The RSLogix 5000 software automatically detects the additional memory once you install the module and cycle power. You must verify that your controller project properties reflect the increased memory capacity to utilize the additional 1 MB for user tags and logic.

  • What precautions should I take during installation?

    Always power down the ControlLogix chassis before inserting the 1756-M2 into the controller. Observe standard ESD (Electrostatic Discharge) protocols by wearing a grounding strap, as memory chips remain highly sensitive to static damage during handling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more