Overview

The Allen-Bradley 1756-IRT8I is an 8-channel ControlLogix isolated analog input module optimized for precise temperature and millivolt (mV) measurements. Designed for thermocouple applications, it offers high-resolution signal acquisition and maintains full electrical isolation between input channels and the backplane.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1756-IRT8I

  • Product Type: ControlLogix Isolated Analog I/O Module

  • Channels: 8 isolated inputs

  • Input Mode: Thermocouple

  • Input Voltage Range: -100 to 100 mV

  • Actual Input Range Capability: -101 to 101 mV

  • Resolution: 24-bit theoretical, 23.98-bit effective across full range

  • Removable Terminal Block: 36-pin (compatible with 1756-TBCH or 1756-TBS6H)

  • Isolation: Each input channel is individually isolated to prevent interference

  • Module Mounting: Standard ControlLogix chassis slot

Key Features

  • High-accuracy 8-channel analog input for thermocouples

  • Individually isolated channels improve system safety and signal integrity

  • Compatible with standard ControlLogix terminal blocks for easy installation

  • Supports millivolt-range signals for precise process monitoring

  • Ideal for temperature and low-voltage sensor integration

Applications

  • Industrial process temperature measurement and monitoring

  • Integration with ControlLogix systems requiring isolated analog inputs

  • High-precision signal acquisition for research or manufacturing processes

FAQs

Q1: What type of signals does the 1756-IRT8I accept?
It supports thermocouple temperature signals and low-voltage millivolt inputs.

Q2: How many inputs are isolated?
All 8 channels are individually isolated for improved safety and reduced cross-talk.

Q3: Which terminal blocks are compatible?
It is compatible with 36-pin 1756-TBCH or 1756-TBS6H removable terminal blocks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more