PRODUCT SKU : 1747-L532

PRODUCT TYPE : Processor

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1747-L532 is a high-performance SLC 5/03 processor designed for SLC 500 PLC systems. It delivers reliable processing of both digital and analog signals with battery-backed memory support. The module efficiently manages large I/O counts while maintaining rapid scan times for real-time control applications.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model Number: 1747-L532

  • Product Type: SLC 5/03 Processor

  • Category: PLC CPU

  • Digital Inputs: 4096

  • Digital Outputs: 4096

  • Analog I/O Points: 480

  • Memory: Up to 16 KB battery-backed RAM

  • User Memory: 16,000 words

  • Program Scan Time: 1 ms per K

  • I/O Scan Time: 0.225 ms

  • Supported I/O Chassis: 3

  • Chassis Slots: 30

  • Communication Ports: DH485, RS-232

  • Ambient Operating Temperature: 0 to 60 °C

  • Backplane Current (5 VDC): 500 mA

  • Battery Backup Memory: Yes, requires 1747-BA

  • Memory Backup Module: 1747-M13

  • Weight: 0.34 kg (0.75 lbs)

Key Features

  • High-density digital and analog I/O support for complex automation tasks

  • Rapid program and I/O scan rates for real-time applications

  • Battery-backed RAM ensures program retention during power loss

  • Compatible with standard SLC 500 chassis with multiple slots

  • Supports serial communication via DH485 and RS-232 for network integration

Application Scenarios

  • Control of mid-sized automation systems using SLC 500 PLCs

  • Integration in manufacturing lines requiring high-speed processing of digital and analog signals

  • Backup-ready configuration for critical process control applications

  • Ideal for SLC 5/03 expansion with multiple I/O modules

FAQ

Q1: What type of memory does the 1747-L532 use?
A1: It uses up to 16 KB battery-backed RAM, with user memory of 16,000 words.

Q2: Which communication protocols are supported?
A2: The module supports DH485 and RS-232 connections for networked PLC systems.

Q3: How many I/O points can this processor manage?
A3: It handles 4096 digital inputs, 4096 digital outputs, and 480 analog points.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more